Based on a suggestion from Greg, I started looking at the ADC-L/ADC-R RX1 meter readings yesterday because I suspect that there may be situations where I'm saturating the ADC on 6M. I'm running PSDR 2.0.0 with a Flex 5000A. On 6M I have an ARR preamp with a measured gain of 26 dB followed by an 8 dB attenuator. This gives me the best weak signal performance in my typical local noise environment.

Here's the interesting observation. With a 96 kHz sample rate, NB1 and NB2 off, -100 dBm (S 4.5) power line noise and no detectable 6M signals in the bandpass, the ADC readings were about -28 dBFS. When I turn on both noise blankers (default settings), the ADC drops to about -48 dBFS. I suspect that the ADC meter samples are being picked up after the noise blanker rather than before it. Shouldn't the ADC meter readings be independent of anything that happens after the ADC (NB, BW, etc)?

73,
Clay W7CE

_______________________________________________
Flexedge mailing list
[email protected]
http://mail.flex-radio.biz/mailman/listinfo/flexedge_flex-radio.biz
This is the FlexRadio Systems e-mail Reflector called FlexEdge.  It is used for 
posting topics related to SDR software development and experimentalist who are 
using beta versions of the software.

Reply via email to