At 07:53 PM 12/22/2005, David Queen wrote:
I take it back. The close in phase noise fro the 9854 on the data sheet seems much better. But still one one "analog" path with a Johnson counter vrs 2 paths on frequency, which would be better?
You need to look at the phase noise of your counter and thresholding circuit (for the Johnson counter). Folks designing high performance microwave PLLs obsess about such things, because they're a significant contributor to overall performance. Don't forget that digital circuitry doesn't have non-zero jitter, and picoseconds make a difference. (If you're sampling a 30 MHz signal (period = 33 ns), a timing error of 1 ps is equivalent to an amplitude sampling error of approximately 1E-12/33E-9, or 30 ppm. (about -90 dBc, if your sinewave happens to be exactly full scale)
James Lux, P.E. Spacecraft Radio Frequency Subsystems Group Flight Communications Systems Section Jet Propulsion Laboratory, Mail Stop 161-213 4800 Oak Grove Drive Pasadena CA 91109 tel: (818)354-2075 fax: (818)393-6875