On Sunday 19 February 2006 19:12, Dave Perry wrote:
> David, would it be possible to have this routine get the normalization
> voltage from the electrical system used by the model?  I don't see any
> such value in the property tree (an ideal_volts such as is defined by
> the nasal electrical system).

While that would fix this particular problem, I think it would be nice if all 
instruments would optionally allow all input properties to be set from XML; 
this would make it much easier to simultaneously have two or more instruments 
of the same type which might IRL have completely different input 
requirements.  (E.g main and standby instruments.)

As far as I know this is already partially possible with some instruments, 
which take config settings like <static-port> and <pitot-port>.

Cheers,

AJ


-------------------------------------------------------