Hi,this patch will propagate zero volt to the output properties when...there is no current at all. Atm if you switch all inputs off (alt & bat switches) you still have 24v at the outputs.
Harald.
Index: electrical.cxx =================================================================== RCS file: /var/cvs/FlightGear-0.9/source/src/Systems/electrical.cxx,v retrieving revision 1.35.2.1 diff -u -r1.35.2.1 electrical.cxx --- electrical.cxx 11 May 2007 18:00:05 -0000 1.35.2.1 +++ electrical.cxx 19 May 2007 09:19:22 -0000 @@ -428,16 +428,16 @@ // zero out the voltage before we start, but don't clear the // requested load values. for ( i = 0; i < suppliers.size(); ++i ) { - suppliers[i]->set_volts( 0.0 ); + suppliers[i]->set_volts( -0.01 ); } for ( i = 0; i < buses.size(); ++i ) { - buses[i]->set_volts( 0.0 ); + buses[i]->set_volts( -0.01 ); } for ( i = 0; i < outputs.size(); ++i ) { - outputs[i]->set_volts( 0.0 ); + outputs[i]->set_volts( -0.01 ); } for ( i = 0; i < connectors.size(); ++i ) { - connectors[i]->set_volts( 0.0 ); + connectors[i]->set_volts( -0.01 ); } // for each "external" supplier, propagate the electrical current
------------------------------------------------------------------------- This SF.net email is sponsored by DB2 Express Download DB2 Express C - the FREE version of DB2 express and take control of your XML. No limits. Just data. Click to get it now. http://sourceforge.net/powerbar/db2/
_______________________________________________ Flightgear-devel mailing list Flightgear-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/flightgear-devel