On Mon, 2004-11-29 at 14:56 -0500, [EMAIL PROTECTED] wrote:
> >Israel,
> >    Please just reply to the list so that anyone esle with a similar
> >problem can have access to the solution.
> >
> 
> you are right edson.. sorry....

No need to apologize. 
> 
> >You can definately export from multiple locatoins to one collector using
> 
> I just did'nt know that multiple exporter could export flows to the same UPD
> port on my netflow server.
> Thanks to you all ...
> 
Glad we could be of service.

> regards
> Israel
> 
> On Mon, 2004-11-29 at 13:23 -0500, [EMAIL PROTECTED] wrote:
> > Hi edson, thanks for your soon answer, BUT, I have read 3 times the man page
> and
> > I can't find what I've looking for..
> > the man page tells me to accept from more than one location using only one 
> > UDP
> > port 9800
> > 
> > from: man page
> > 
> > EXAMPLES
> > 
> > Receive flows from the exporter at 10.0.0.1 port 9800. Maintain 5 Gigabytes 
> > of
> > flow files in /flows/krc4. Mask the source and destination IP addresses
> > contained in the flow exports with 255.255.248.0.
> > 
> > flow-capture -w /flows/krc4 -m 255.255.248.0 -E5G 0/10.0.0.1/9800
> > 
> > Or can I set my 3 cisco to export flows to the same udp port on my netflow
> > server? I dont think so..
> > 
> > Can you help me please!
> > 
> > Saludos
> > 
> > Israel Garcia Alvarez
> > Linux Counter User #196178
> > Corporacion CIMEX Villa Clara
> > 
> > 
> > 
> > -----Mensaje original-----
> > De: Edson Manners <[EMAIL PROTECTED]> 
> > Enviado el: Monday, November 29, 2004 11:59 AM
> > Para: SV-Israel Garcia
> > Asunto: Re: [Flow-tools] multiple exporters 
> > 
> > 
> > The flow-capture man page shows ways of telling flow capture to accept
> > flows from more than one location. If that still doesn't make sense ask
> > again and I'll gladly help.
> > 
> > On Mon, 2004-11-29 at 08:58 -0500, [EMAIL PROTECTED] wrote:
> > > Hi:
> > > I have 3 cisco routers [netflow v5], exporting flows to my flow-tool's
> server.
> > > 
> > > [cisco1] ---> port UDP 9999
> > > [cisco2] ---> port UDP 9998
> > > [cisco3] ---> port UDP 9997
> > > 
> > > so, I want flow-tools to process all this flows in only one
> > > file-->[ft-v05.2004-11-29.085000-0500] on a especified
> > > directory-->[/var/local/flows].....Can floot-capture do that?
> > > 
> > > 
> > > regards...
> > > 
> > > Israel Garcia Alvarez
> > > Linux Counter User #196178
> > > Corporacion CIMEX Villa Clara
> > > 
> > > 
> > > _______________________________________________
> > > Flow-tools mailing list
> > > [EMAIL PROTECTED]
> > > http://mailman.splintered.net/mailman/listinfo/flow-tools
-- 
Edson Manners
Academic Computing & Networking Services
Florida State University
(850)644-2591 ext. 144
_______________________________________________
Flow-tools mailing list
[EMAIL PROTECTED]
http://mailman.splintered.net/mailman/listinfo/flow-tools

Reply via email to