Hi all,
I met with a netflow problem.

I configured netflow on cisco cat6506
(IOS (tm) c6sup2_rp Software (c6sup2_rp-PSV-M), Version 12.2(18)SXD3)

The traffic on that device is about 100M.
But when I monitor using flowscan, the traffic is only about 10k.

My netflow configuration is just:
ip route-cache flow

Have you ever met with such problem?

yours sincerely
haina tang
_______________________________________________
Flow-tools mailing list
[EMAIL PROTECTED]
http://mailman.splintered.net/mailman/listinfo/flow-tools

Reply via email to