>From: "Monty Ree" <[EMAIL PROTECTED]>
{snip]
>But my flow files are created like below.
>
>/home/netflow/ft/tmp-v05.2007-02-07.165000+0900
>
>-. What should I do to leave flow-files like 
>"/home/netflow/ft/F19/2007/2007-02/2007-02-07"?
>
>-. What I would like to do is monitoring flow-files per
>interface(customer) 
>as I wrote at previous mail.
>
>-.Any more documents about FlowViewer?
>
>-. There is a device variable like below.
>  @devices = ("F19","F20");

Since you only have one device set

@devices = ();
$flow_directory = /home/netflow/ft

>  Then Should I leave the flow-files per interface?I is possible?
>
>
>* my flow-capture is below.
># flow-capture -w /home/netflow/ft 0/0/2060 -S5 -V5 -E1G -n 287 -N 0
>-R 
>/usr/local/netflow/bin/linkme

Leave off the -N 0 and you will get the yr/mon/day format you want.

Contact me off-list if it's still not going. Glad to help ...

Joe
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
This is a PRIVATE message. If you are not the intended recipient, please delete without copying and kindly advise us by e-mail of the mistake in delivery. NOTE: Regardless of content, this e-mail shall not operate to bind CSC to any order or other contract unless pursuant to explicit written agreement or government initiative expressly permitting the use of e-mail for such purpose.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------