A Flume agent started before collectors in E2E mode could fail to connect to 
the collector
------------------------------------------------------------------------------------------

                 Key: FLUME-927
                 URL: https://issues.apache.org/jira/browse/FLUME-927
             Project: Flume
          Issue Type: Bug
          Components: Sinks+Sources
    Affects Versions: v0.9.4, v0.9.5
            Reporter: Prasad Mujumdar
            Assignee: Prasad Mujumdar
             Fix For: v0.9.5


The write ahead log (WAL) mechanism expects the agent sink to be active in 1 
second. After that, it assumes that the agent couldn't connect to collector and 
shuts it down. The AgentSink has a retry mechanism that handles network 
problems, unavailable collector etc for a configurable amount of time. The 
hardcode 1 sec timeout in WAL decorator invalidates this retry mechanism. 


--