First off, thanks for the hard work that has been put together to document 
and create scripts for the process of Windows deployments using DISM and 
wimaging.

I've got a fully functional workflow for deploying Windows 2012 R2 boxes, 
however, it only works when the WinPE environment can call 
/unattended/script directly against foreman.

When a smart-proxy is being used, the call from 10_init.cmd is sent to the 
proxy instead and the source IP of the originating host gets lost, so the 
template can't be generated.

I'm trying to think of the best way around this when a smart-proxy is 
involved.

It's possible that for Windows deploys we will have to allow access to the 
foreman master for /unattended/script call so that the source IP is 
maintained.

I could disable login and use the spoof parameter to have the PE 
environment grab the appropriate template.

I can't use tokens as would normally be recommended in this type of 
workflow because I can't figure out a way to get the token into the WinPE 
10_init.cmd script or config file as these are built into the DISM created 
wimage.

Is there anything I'm missing that would make this work?

-- 