Will only affect the mtu on the data flowing through the device. I've had a chat with foundry and at the moment the MLX do not support higher mtu on the traffic that originate from the device itself, but on traffic that's being switched/routed trough it will handle a big mtu.
/rickhard On Tue, 2006-07-18 at 12:50 +0200, Gunther Stammwitz wrote: > Change/Increase the MTU for the real interface, this should work. > > Gunther > > > -----Urspr?ngliche Nachricht----- > > Von: foundry-nsp-bounces at puck.nether.net > > [mailto:foundry-nsp-bounces at puck.nether.net] Im Auftrag von > > Rickhard Carlsw?rd > > Gesendet: Mittwoch, 12. Juli 2006 09:48 > > An: foundry-nsp at puck.nether.net > > Betreff: [f-nsp] ip mtu > > > > Hello all, > > > > I'm in the process of replacing a RX-4 with a MLX-4 but I > > just discovered that I can't change the MTU on the vif in the MLX. > > > > On the RX-4 I just have: > > > > interface ve 116 > > ip address xxx.xxx.xxx.xx/24 > > ip mtu 4470 > > > > But on the MLX im not able to set the MTU over 1500. > > So do anyone have any idea how I can change the MTU for a vif > > in the MLX? > > > > /rickhard > > > > _______________________________________________ > > foundry-nsp mailing list > > foundry-nsp at puck.nether.net > > http://puck.nether.net/mailman/listinfo/foundry-nsp > > > > > > > _______________________________________________ > foundry-nsp mailing list > foundry-nsp at puck.nether.net > http://puck.nether.net/mailman/listinfo/foundry-nsp