Jonathan Brashear wrote:
Our DC has had intermittent issues over the past year with spanning-tree loops with 
customers who have multiple uplinks to our switch fabric.  We've explored a few 
different options with limited to no success(such as bpdu guard, stp-protect, 
etc.), but currently we're considering setting manual path costs on ports as a way 
to help avoid the loops & subsequent cpu spikes we've dealt with.  Has anyone 
deployed manual path costs for customers with multiple uplinks(either to the same 
switch or multiple switches), and if so what success/problems have you had with its 
implementation?  I'd prefer the info be from the FastIron environment, but any 
Foundry-related discussion would be appreciated.


I've had relatively good success using pvst mode and multiple paths on both the FESX and RX line. Even when using other switch vendors at the edge it seems to work well. Setting the cost has seemed to work well too - although I typically set those at the edge. Per their manual the interfaces default into an mstp mode and can under certain circumstance switch to pvst, setting it expressly as "pvst-mode" on the interface helps mitigate looping and other "weirdness" in my experience.

Regards,

        Chris
_______________________________________________
foundry-nsp mailing list
[email protected]
http://puck.nether.net/mailman/listinfo/foundry-nsp

Reply via email to