Dear Lazuardi:
The following are the sample configuration you have asked. Let's say the inner voice vlan id is 101, inner data vlan id is 102, the outter q-in-q vlan id is 901. You will find that the vlan id 101 & 102 didn't use in those device. This because that the vlan id 101 & 102 are looked as payload. The QoS setting of vlan id 101 and 102 will follow the vlan id 901. You may use 'aggregtaed-vlan-copy-cos' or 'qos decode-cvlan-pcp' command to have MLX copy the inner vlan qos to outter vlan. However, FESX didn't support this feature. Regards, Spenser. ----------------------------------------------------------------------------------------------------- For FESX-A jumbo aggregated-vlan tag-type 9100 ethernet 13 to 24(the ports to connect Q-in-Q customers) vlan 901 untag e 13(the ports to connect Q-in-Q customer) tag 1 (uplink port) ----------------------------------------------------------------------------------------------------- For FESX-B jumbo aggregated-vlan tag-type 9100 ethernet 13 to 24(the ports to connect Q-in-Q customers) vlan 901 untag e 13(the port to connect Q-in-Q customer) tag 1 (uplink port) ----------------------------------------------------------------------------------------------------- For MLX default-max-frame-size 9216 tag-type 9100 e 3/1(the port connect to Node C cutomer) vpls Q-in-Q-test 901 cos 1(cos 0-7 is optional) vlan 901 tag e 3/2(the port connect to FESX-A & FESX-B) untag e 3/1(the port connect to Node C cutomer) ------------------------------------------------------------------------------------------
_______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp