Is there enough power available in the chassis ?, I've had issues with booting up a single linecard if there was only 1 powersupply connected.

Chuck Ufarley wrote:
Hi all--

I've got a couple of NI-MLX-1Gx20-SFPs that I'm trying to bring up on an NI-MLX-MR running 4.00ca, and I can't get the cards to boot. They keep looping through a "CARD_STATE_BOOT" "CARD_STATE_SW_LOADED " "CARD_STATE_SYNC_FID" loop, but won't come up active. I can't update the lp files unless the card comes up. I've tried this:

Config t
 lp boot system interactive [slot#]
exit
 wr mem
Power-off lp [slot#]
Power-on lp [slot#]
lp boot system mp primary [slot#]

and the lp images load from the mp, but they don't seem to stick, because the line card doesn't go active.

Do I need to issue a "no lp boot system interactive" + new "wr mem" + reload command to get it up and running? It doesn't seem to work. Am I missing something obvious.

Help is extremely appreciated.  I'm a little stumped right now.

Thanks.

--Chuck
------------------------------------------------------------------------

_______________________________________________
foundry-nsp mailing list
[email protected]
http://puck.nether.net/mailman/listinfo/foundry-nsp

--