Is there enough power available in the chassis ?, I've had issues with
booting up a single linecard if there was only 1 powersupply connected.
Chuck Ufarley wrote:
Hi all--
I've got a couple of NI-MLX-1Gx20-SFPs that I'm trying to bring up on
an NI-MLX-MR running 4.00ca, and I can't get the cards to boot. They
keep looping through a "CARD_STATE_BOOT" "CARD_STATE_SW_LOADED "
"CARD_STATE_SYNC_FID" loop, but won't come up active. I can't update
the lp files unless the card comes up. I've tried this:
Config t
lp boot system interactive [slot#]
exit
wr mem
Power-off lp [slot#]
Power-on lp [slot#]
lp boot system mp primary [slot#]
and the lp images load from the mp, but they don't seem to stick,
because the line card doesn't go active.
Do I need to issue a "no lp boot system interactive" + new "wr mem" +
reload command to get it up and running? It doesn't seem to work. Am
I missing something obvious.
Help is extremely appreciated. I'm a little stumped right now.
Thanks.
--Chuck
------------------------------------------------------------------------