Hi all-- I'm trying to bring up a WSM7 with 11.01, and I'm having a little trouble. Alone, it gives me this error at bootup:
WARN: Failed to copy system code to module 2(1) because of wrong ext code size 0 0000000 WARN: Failed to copy system code to module 2(2) because of wrong ext code size 0 0000000 But if I load it as a standby module, it comes up fine, syncs fine. When I failover, it boots and gives the above error again. WSM initialization tries to come up, and I can get the # prompt, but a show flash gives me this: SLB-ServerIron 450>sho fla Active management module: Code Flash Type: AMD 29LV033C, Size: 64 * 65536 = 4194304, Unit: 4 Boot Flash Type: AMD 29LV040B, Size: 8 * 65536 = 524288 Compressed Pri Code size = 5569101, Version 11.0.00bTG2 (WZM11000b.bin) Compressed Sec Code size = 5569101, Version 11.0.00bTG2 (WZM11000b.bin) Maximum Code Image Size Supported: 6946304 (0x0069fe00) Boot Image size = 297120, Version 11.0.01 (m3b11000b.bin) INFO: empty config data in the primary area, try to read from backup INFO: empty config data in the backup area also Configuration Data Flash is empty. Used Configuration Flash Size=0, Max Configuration Flash Size=327680. WSM module slot 2 CPU 1: Code Flash Type: , Size: 0 * 0 = 0 Boot Flash Type: , Size: 0 * 0 = 0 Compressed Pri Code: size = 0 Version Compressed Sec Code: size = 0 Version Maximum Code Image Size Supported: 0 (0x00000000) Boot Image size = 0 Version Maximum Boot Image Size Supported: 0 (0x00000000) WSM module slot 2 CPU 2: Code Flash Type: , Size: 0 * 0 = 0 Boot Flash Type: , Size: 0 * 0 = 0 Compressed Pri Code: size = 0 Version Compressed Sec Code: size = 0 Version Maximum Code Image Size Supported: 0 (0x00000000) Boot Image size = 0 Version Maximum Boot Image Size Supported: 0 (0x00000000) WSM module slot 2 CPU 3: Code Flash Type: , Size: 0 * 0 = 0 Boot Flash Type: , Size: 0 * 0 = 0 Compressed Pri Code: size = 0 Version Compressed Sec Code: size = 0 Version Maximum Code Image Size Supported: 0 (0x00000000) Boot Image size = 0 Version Maximum Boot Image Size Supported: 0 (0x00000000) SLB-ServerIron 450> This suggests that the files aren't even there on the WSM mods, though they appear with a show flash when the same card is a standby. Again, syncing is fine, codes are identical. Anyone got any ideas as to why that's happening? As always, your help is greatly appreciated. Thanks. --Chuck
_______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp