It is possible. I am using 4.0.0.1d. I have tied local ve with vpls without looping.
Vpls end point port is tagged or untagged going to a switch. Switch has same vlan tagged or untagged on different port for same vlan coming back to router for local ve. You are creating physical looped topology but it is not a logical loop. Thanks, Pritesh -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Mike Hughes Sent: Tuesday, June 15, 2010 11:47 AM To: [email protected] Subject: Re: [f-nsp] ve in VPLS on NetIron XMR? --On 15 June 2010 13:42 -0500 Brad Fleming <[email protected]> wrote: > We're running IronWare 4.0.0.1d on NetIron XMRs. Is it possible to tie a > local VE into a VPLS without looping ports together? > > Based upon the ConfigGuide, I don't think its possible without looping > ports but I thought I'd ask... figure some of you all have been down this > road and know the answer already. VEs into VPLS should be supported in 5.0.0 and later. Mike -- Mike Hughes Chief Technical Officer London Internet Exchange Ltd. [email protected] http://www.linx.net/ Registered in England 3137929 at Trinity Court, Peterborough, PE1 1DA _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp