Hello,

We recently upgraded our network and replaced an old Netgear switch with a 
FastIron SuperX-PREM switch. This new switch has a FI424C (24x copper) module 
and the FI12GM management module with 12 SFP/Copper combo ports. The software 
loaded is the L3 code version 05.1.00T3e3.

The switch runs fine when we use one module at a time, but seems to drop 
packets when we try to use ports on both modules at the same time (e.g. when 
transmitting data from port 1/1 to 9/1). This very strange behaviour does not 
affect any traffic occuring between ports on the same module. We tried changing 
optics and even using copper ports on the management module, with no success.
At the moment and until this problem is solved, we are only using Layer 2 
forwarding and tagged vlans, disabled everything else such as STP/RSTP 
functions.

Does anyone have experienced the same thing on this model ?

Thanks,
Gabriel
_______________________________________________
foundry-nsp mailing list
[email protected]
http://puck.nether.net/mailman/listinfo/foundry-nsp

Reply via email to