Hi Justin, I saw your problem with the XMR 10G blade, but the problem is harder then I expected.
Lets go: 1. Removed blade from slot 2. 2. Sh mod: S2: Configured as BIMG8-10Gx4-v6 4-port 10GbE IPv4/v6 Module Log: Nov 18 14:20:17:N:Module was removed from slot 2 But the slot is already configured with the right module. I will remove the config and reconfigure it: 3. (config)#no mod 2 bimg8-v6-10g-4-port 4. (config)#module 2 bimg8-v6-10g-4-port 5. Sh mod: S2: Configured as BIMG8-10Gx4-v6 4-port 10GbE IPv4/v6 Module 6. Insert module: S2: Invalid Module CARD_STATE_DOWN (7) (previous state = CARD_STATE_SW_LOADED) End after the module startup: S2: BIMG8-10Gx4-v6-A 4-port 10GbE IPv4/v6 Module (OACL) CARD_STATE_INTERACTIVE 0 It might be a bigger problem. This (new) module is an A module: BIMG8-10Gx4-v6-A Our other modules: M1 (upper): BIMG8-MR Management Module Active M2 (lower): F1: BIMG8-SFM Switch Fabric Module Active S1: S2: BIMG8-10Gx4-v6-A 4-port 10GbE IPv4/v6 Module (OACL) CARD_STATE_INTERACTIVE 0 S3: S4: S5: S6: S7: BIMG8-1Gx40-SFP-v6 40-port 1 GbE IPv4/v6 Module (IPv6+OACL) CARD_STATE_UP 40 Extra logging: Nov 18 14:26:07:N:Module 2 is reset by mgmt (reason: boot to interactive mode) Nov 18 14:25:38:N:Module was inserted to slot 2 Nov 18 14:20:17:N:Module was removed from slot 2 Nov 18 13:36:35:N:Module 2 is reset by mgmt (reason: boot to interactive mode) Nov 18 13:36:10:N:Module 2 is reset by mgmt (reason: CLI command) Nov 18 13:24:17:N:Module 2 is reset by mgmt (reason: boot to interactive mode) Nov 18 13:23:48:N:Module 2 is reset by mgmt (reason: lp sync during booting) Nov 18 13:22:19:N:Module was inserted to slot 2 The module is forced to interactive mode by the management. It might be a software problem.. Kind regards, Dominic On Thu, Nov 18, 2010 at 3:17 PM, Justin Suyk - Signet BV <[email protected]>wrote: > Hi, > > We had to remove the blade before changing the config. > So : > > 1. remove module > 2. remove the blade config (no module ... bi-...) > 3. config the blade > 4. insert the blade > 5. get a beer > > > Regards, > Signet bv > > > Justin Suyk > > T 040 - 707 4 907 > F 040 - 707 4 909 > Kvk 17089930 > > > > On 11/18/2010 03:11 PM, Dominic Douglas wrote: > > > *Hi All, > > We do have a problem with one of our MG8 switches. We've added a new > BIMG8-10Gx4-v6-A blade, but after configuration the blade will not recover > from CARD_STATE_INTERACTIVE. > > S2: BIMG8-10Gx4-v6-A 4-port 10GbE IPv4/v6 Module (OACL) > CARD_STATE_INTERACTIVE 0 000c.db27.4560 > > Steps taken: > > 1. Reset module. > 2. Set type to the slot port. > 3. Turn on/off module. > > Unfortunately we can't find any logs about the new blade, only the current > state: **CARD_STATE_INTERACTIVE. > > Kind regards, > > Dominic > ** > > * > > > _______________________________________________ > foundry-nsp mailing > [email protected]http://puck.nether.net/mailman/listinfo/foundry-nsp > >
_______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp