Hello,
I have stumbled upon a limitation that I can't seem to find any workaround for. I have the following setup per-pop : MLXe ========== FCS stack (2 members) =========== Management interfaces of devices (switchs, PDUs, firewalls, etc.) I created a managment VRF that spans multiple POPs, each has it's IP private space. A Vlan (on the MLXe) is binded to a VRF, the VLAN is trunked down to a stack of switchs (using a LAG) in order to aggregate cabling. Problem I have is the following : I can't use the dedicated managment interface on the MLX MR2 modules because the chassis only has one mac-address. So, when I plug in the cable to the aggregation switchs, mac-address is not learned from that port but rather from the LAG. Otherwise, I would create a nice L2 loop ;-) This on the MLX : Ethernetmgmt1 is down, line protocol is down STP Root Guard is disabled, STP BPDU Guard is disabled Hardware is Ethernet, address is *0024.38a5.7b00 (bia 0024.38a5.7b00)* This is on the FCS stack switchs : telnet@ag01-par01#sh mac-address Total active entries from all ports = 35 MAC-Address Port Type Index VLAN .... *0024.38a4.fb00 1/1/1*2/1/1 Dynamic 28312 100* N.B : e1/1/1 and 2/1/1 are the ports used to create uplink LAG to the MLX router / VLAN100 is the managment VLAN bounded to the management VRF. For operational needs, I would really like to use the dedicated management interface on the MLX routers (authentication, supervision/monitoring, etc.). Sadly, there is nothing you can do on that interface except change the IP address :-/ Has anyone faced this before ? Any workaround you can think of ? Best. Y.