I wouldn't hold your breath. Last I was told this is an architecture limitation on the MLX(e) platform. However, uRPF can be configured on a physical interface and will be processed for each VLAN/VE that traverses that physical interface.
Caveat: uRPF is disabled on a physical interface IF a VLAN on that interface has a VE that is not in the default VRF. Yes, you should beat your account reps up about this. :) /Ryan Ryan Harden Senior Network Engineer University of Chicago - AS160 P: 773-834-5441 On Aug 29, 2013, at 3:05 PM, Brad Fleming <[email protected]> wrote: > Any chance someone on the list knows if / when the XMR or MLXe series will be > able to do reverse path checks on VE interfaces? > _______________________________________________ > foundry-nsp mailing list > [email protected] > http://puck.nether.net/mailman/listinfo/foundry-nsp
signature.asc
Description: Message signed with OpenPGP using GPGMail
_______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp