I wouldn't hold your breath. Last I was told this is an architecture limitation 
on the MLX(e) platform.
However, uRPF can be configured on a physical interface and will be processed 
for each VLAN/VE that traverses that physical interface. 

Caveat: uRPF is disabled on a physical interface IF a VLAN on that interface 
has a VE that is not in the default VRF.

Yes, you should beat your account reps up about this. :)

/Ryan

Ryan Harden
Senior Network Engineer
University of Chicago - AS160
P: 773-834-5441




On Aug 29, 2013, at 3:05 PM, Brad Fleming <[email protected]> wrote:

> Any chance someone on the list knows if / when the XMR or MLXe series will be 
> able to do reverse path checks on VE interfaces?
> _______________________________________________
> foundry-nsp mailing list
> [email protected]
> http://puck.nether.net/mailman/listinfo/foundry-nsp

Attachment: signature.asc
Description: Message signed with OpenPGP using GPGMail

_______________________________________________
foundry-nsp mailing list
[email protected]
http://puck.nether.net/mailman/listinfo/foundry-nsp

Reply via email to