Hi all, We used the unified software image for upgrading some BigIron RX routers (loaded with two MP's) to the latest firmware available. After copying the unified software image, we rebooted the management module using the reload command. Problems arise when the synchronization starts to the standby MP.
========================================================= "router>All tasks have completed their initializations Start code flash synchronization to standby MP. Code flash synchronization to standby MP is done. Error:itc_send_running_config_req: sys_allocate_global_memory() failed " ========================================================= or when you put in the standby MP after loading the primary MP: ========================================================= "Standby MP inserted SYSLOG: <13>Apr 30 11:29:19 router, Management module 2 was inserted Start code flash synchronization to standby MP. Code flash synchronization to standby MP is done. Error:itc_send_running_config_req: sys_allocate_global_memory() failed Start cli mode synchronization to standby MP. Session 0 cli mode synchronization to standby MP is done. " ========================================================= Has someone seen this issue before? I think we can work around this issue by syncing the MP's with an empty config and copying the configuration over again. Obviously this is a far from ideal solution. This didn't happen on every router with the firmware, but the same happened before with different routers and different firmwares in the past. I'm wondering why it complains about "sys_allocate_global_memory() failed". We changed some default values ( lowered the amount of possible virtual instances to increase the max ip-route and ip-cache values). Maybe it is time to create a ticket with Brocade, but maybe some of you have experienced the same problem :) thanks in advance Joeri _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp