Hi all-- This is more like a disaster. Had a power failure on a BI-RX16-AC running 2.900c. One power tripped the breaker, and after another trip and a reboot, the whole thing wouldn't come up, and all the EEPROMs seem to have "failed." Can one rogue power fry an entire 16-slot RX chassis? Anyone seen this before? There's no way to replace the EEPROM chips, right? I doubt this is recoverable, but if anyone's got a tip, I'd love to hear it.
Here's a sample from the boot process: SNM4/FE2 initialization successful. SNM4/FE3 initialization successful. AC Power Supply 1 is Installed (OK) Power Supply 2 is Not Installed (FAILED) Warn:rw_read_power_supply_reg: valere_i2c_read() (ret = 32) && cherokee_i2c_read() (ret = -2) failled Warn:rw_read_power_supply_reg: rw_unselect_mux() failed for mux 0 (ret = -2) Error:rw_check_a_power_status: can't read power supply 2 model_number register AC Power Supply 3 is Installed (OK) Error:rw_select_mux_channel: channel: written = 5, read = 0 Warn:rw_read_power_supply_reg: rw_select_mux_channel() failed for mux 0 channel 5 (ret = -1) Error:rw_check_a_power_status: can't read power supply 3 model_number register AC Power Supply 4 is Installed (OK) Power Supply 5 is Not Installed (FAILED) Power Supply 6 is Not Installed (FAILED) Power Supply 7 is Not Installed (FAILED) Power Supply 8 is Not Installed (FAILED) Error:rw_select_mux_channel: channel: written = 0, read = 0 Warn:rw_read_at24c02a_eeprom: rw_select_mux_channel() failed for mux 0 channel 0 (ret = -1) Warn:get_lp_pwr_usage: read LP EEPROM failed for slot 1 Slot 1 will not be powered on. Error:rw_select_mux_channel: channel: written = 0, read = 0 Warn:rw_read_at24c02a_eeprom: rw_select_mux_channel() failed for mux 0 channel 0 (ret = -1) Warn:get_lp_pwr_usage: read LP EEPROM failed for slot 3 Slot 3 will not be powered on. Error:rw_select_mux_channel: channel: written = 1, read = 0 Warn:rw_read_at24c02a_eeprom: rw_select_mux_channel() failed for mux 0 channel 1 (ret = -1) Warn:get_lp_pwr_usage: read LP EEPROM failed for slot 6 Slot 6 will not be powered on. Error:rw_select_mux_channel: channel: written = 1, read = 0 Warn:rw_read_at24c02a_eeprom: rw_select_mux_channel() failed for mux 0 channel 1 (ret = -1) Warn:get_lp_pwr_usage: read LP EEPROM failed for slot 8 Slot 8 will not be powered on. Error:rw_select_mux_channel: channel: written = 3, read = 0 Warn:rw_read_at24c02a_eeprom: rw_select_mux_channel() failed for mux 0 channel 3 (ret = -1) Warn:get_lp_pwr_usage: read LP EEPROM failed for slot 10 Slot 10 will not be powered on. Error:rw_select_mux_channel: channel: written = 2, read = 0 Warn:rw_read_at24c02a_eeprom: rw_select_mux_channel() failed for mux 0 channel 2 (ret = -1) Warn:get_lp_pwr_usage: read LP EEPROM failed for slot 13 Slot 13 will not be powered on. Error:rw_select_mux_channel: channel: written = 2, read = 0 Warn:rw_read_at24c02a_eeprom: rw_select_mux_channel() failed for mux 0 channel 2 (ret = -1) Warn:get_lp_pwr_usage: read LP EEPROM failed for slot 15 Slot 15 will not be powered on. Error:rw_select_mux_channel: channel: written = 0, read = 0 Warn:rw_read_at24c02a_eeprom: rw_select_mux_channel() failed for mux 0 channel 0 (ret = -1) WARN: Can't get manufacture information for switch fabric Error:rw_select_mux_channel: channel: written = 1, read = 0 Warn:rw_read_at24c02a_eeprom: rw_select_mux_channel() failed for mux 0 channel 1 (ret = -1) WARN: Can't get manufacture information for switch fabric Error:rw_select_mux_channel: channel: written = 2, read = 0 Warn:rw_read_at24c02a_eeprom: rw_select_mux_channel() failed for mux 0 channel 2 (ret = -1) WARN: Can't get manufacture information for switch fabric Error:rw_select_mux_channel: channel: written = 3, read = 0 Warn:rw_read_at24c02a_eeprom: rw_select_mux_channel() failed for mux 0 channel 3 (ret = -1) WARN: Can't get manufacture information for switch fabric Error:rw_select_mux_channel: channel: written = 6, read = 0 Warn:rw_read_24aa64_eeprom: rw_select_mux_channel() failed for mux 0 channel 6 (ret = -1) Error:rw_select_mux_channel: channel: written = 6, read = 0 Warn:rw_write_24aa64_eeprom: rw_select_mux_channel() failed for mux 0 channel 6 (ret = -1) BOOTP: init relay agent, port closed 0 PIM4: Initialized for 2345 interfaces PIM6: Initialized for 2345 interfaces Load config data from flash memory... Error:rw_get_power_on_mask: Can't get power usage for slot 3, fail to bring it up Error:rw_get_power_on_mask: Can't get power usage for slot 6, fail to bring it up Error:rw_get_power_on_mask: Can't get power usage for slot 8, fail to bring it up Error:rw_get_power_on_mask: Can't get power usage for slot 10, fail to bring it up Error:rw_get_power_on_mask: Can't get power usage for slot 13, fail to bring it up Error:rw_get_power_on_mask: Can't get power usage for slot 15, fail to bring it up INFO: Enough power available now to power on slot 1 Error:rw_select_mux_channel: channel: written = 6, read = 0 Warn:rw_read_24aa64_eeprom: rw_select_mux_channel() failed for mux 0 channel 6 (ret = -1) ACL configured, you must not change SSH port number INFO: Enough power available now to power on slot 3 switch-phx-11>INFO: Enough power available now to power on slot 6 All tasks have completed their initializations Error:rw_select_mux_channel: channel: written = 7, read = 35 Warn:rw_read_thermal_sensor_reg: rw_select_mux_channel() failed for mux 0 channel 7 (ret = -1) Error:rw_read_temperature_LM95221: rw_read_thermal_sensor_reg() failed (ret = -1) WARN: Can't read active mgmt's temperature! Error:rw_select_mux_channel: channel: written = 0, read = 35 Warn:rw_read_thermal_sensor_reg: rw_select_mux_channel() failed for mux 0 channel 0 (ret = -1) Error:rw_read_temperature_LM75: rw_read_thermal_sensor_reg() failed for temperature register (ret = -1) WARN: Can't read SNM1 temperature! Start code flash synchronization to standby MP. Code flash synchronization to standby MP is done. Error:rw_select_mux_channel: channel: written = 1, read = 35 Warn:rw_read_thermal_sensor_reg: rw_select_mux_channel() failed for mux 0 channel 1 (ret = -1) Error:rw_read_temperature_LM75: rw_read_thermal_sensor_reg() failed for temperature register (ret = -1) WARN: Can't read SNM2 temperature! Error:rw_select_mux_channel: channel: written = 2, read = 35 Warn:rw_read_thermal_sensor_reg: rw_select_mux_channel() failed for mux 0 channel 2 (ret = -1) Error:rw_read_temperature_LM75: rw_read_thermal_sensor_reg() failed for temperature register (ret = -1) WARN: Can't read SNM3 temperature! _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp