All, I think the answer to this should be easy, but I'm unable to figure it out!
I have a unit that was taken out of an extant FCX stack. It happens to be unit 2. I now want it to be unit 1. I've been through pages like http://www.brocade.com/content/html/en/configuration-guide/fastiron-08030b-switchstackingguidehttp://www.brocade.com/content/html/en/configuration-guide/fastiron-08030b-switchstackingguide and tried lots of variants of stack unconfigure me, stack disable, no stack enable, but try as I might I cannot get this unit to revert to being unit 1. The recommendation of running "stack secure-setup" doesn't do anything useful: SSH@#stack secure-setup SSH@#Discovering the stack topology... Selected Topology: Active Id Type Mac Address 2 FCX648S 0024.38c0.bf80 No other units were discovered... ! ver 08.0.10mT7f1 ! stack unit 2 module 1 fcx-48-port-management-module module 2 fcx-cx4-2-port-16g-module module 3 fcx-xfp-2-port-10g-module priority 128 stack-port 2/2/1 2/2/2 stack enable stack mac 0024.38bf.fb00 ... Anyone any ideas? UNIT 2: compiled on Jul 08 2015 at 16:18:42 labeled as FCXS08010m Jethro. . . . . . . . . . . . . . . . . . . . . . . . . . Jethro R Binks, Network Manager, Information Services Directorate, University Of Strathclyde, Glasgow, UK The University of Strathclyde is a charitable body, registered in Scotland, number SC015263. _______________________________________________ foundry-nsp mailing list foundry-nsp@puck.nether.net http://puck.nether.net/mailman/listinfo/foundry-nsp