Hi,

the FoxConsole is already inverting the pins so you need only to connect 
the Fox Console DB9 connector with a straight serial cable to your PC 
serial port.
Set no hardware flow control and you need only to connect 2-2; 3-3; 5-5. 
You can also use a standard complete straight cable with 9 wires 
female-male to connect the FoxConsole to your serial PC port.

Also the default connection parameters for the ttyS0 debug/console 
serial port are: 115200, N, 8, 1.

Best regards,

Roberto Asquini

hrmvb ha scritto:
>
> I just plugged it into the FoxServe board, connected a null modem
> cable (see pin-out) between PC and Foxconsole, configured
> Hyperterminal for 19200N81, no flow control, but I don't get anything
> in Hyperterminal.
>
> null modem cable
> pins pins
> -----------
> 1,6 - 4
> 2 - 3
> 3 - 2
> 4 - 1,6
> 5 - 5
> 7 - 8
> 8 - 7
>
> Does anybody know how to check which part has problems, cable or
> Foxconsole?
>
> - Harm
>
> 
>
> __________ Informazione NOD32 2187 (20070413) __________
>
> Questo messaggio รจ stato controllato dal Sistema Antivirus NOD32
> http://www.nod32.it


-- 
Roberto Asquini
Acme Systems srl
[EMAIL PROTECTED]
http://www.acmesystems.it

Reply via email to