<DIV><SPAN class=520334307-06042001><FONT face=Arial color=#0000ff 
size=2>Checkpointing does NOT save operator set values like alarm setting PID 
setting and the like.</FONT></SPAN></DIV>
<DIV><SPAN class=520334307-06042001><FONT face=Arial color=#0000ff 
size=2></FONT></SPAN>&nbsp;</DIV>
<DIV><SPAN class=520334307-06042001><FONT face=Arial color=#0000ff size=2>This 
would require an upload from the block, compound or station.</FONT></SPAN></DIV>
<DIV><SPAN class=520334307-06042001><FONT face=Arial color=#0000ff size=2>An ICC 
driver script could do this on a timely interval. It is NOT performed 
automatically.</FONT></SPAN></DIV>
<DIV><SPAN class=520334307-06042001><FONT face=Arial color=#0000ff 
size=2>Uploads can be done from the Integrated Control Configurator itself. The 
station upload is done from the Maint menu pick, Compund and block upload can be 
performed from the upload pick in the center window in ICC.</FONT></SPAN></DIV>
<DIV><SPAN class=520334307-06042001><FONT face=Arial color=#0000ff 
size=2></FONT></SPAN>&nbsp;</DIV>
<DIV><SPAN class=520334307-06042001><FONT face=Arial color=#0000ff size=2>Hope 
this helps</FONT></SPAN></DIV>
<DIV><SPAN class=520334307-06042001><FONT face=Arial color=#0000ff 
size=2></FONT></SPAN>&nbsp;</DIV>
<DIV><SPAN class=520334307-06042001>
<P><FONT face=Arial color=#000000 size=2>Ron Deen</FONT> <BR><FONT face=Arial 
color=#000000 size=2>Foxboro Nederland N.V.</FONT> <BR><FONT face=Arial 
color=#000000 size=2>Baarnschedijk 10</FONT> <BR><FONT face=Arial color=#000000 
size=2>3741 LS Baarn</FONT> <BR><FONT face=Arial color=#000000 size=2>The 
Netherlands</FONT> <BR><FONT face=Arial color=#000000 size=2>Phone:&nbsp; 
+31(0)35-5484174</FONT> <BR><FONT face=Arial color=#000000 
size=2>Fax:&nbsp;&nbsp;&nbsp; +31(0)35-5484175</FONT> <BR><FONT face=Arial 
color=#000000 size=2>Web:&nbsp;&nbsp;&nbsp; www.foxboro.com</FONT> <BR><FONT 
face=Arial color=#000000 size=2>e-mail: [EMAIL PROTECTED]</FONT> 
</P></SPAN></DIV>
<BLOCKQUOTE dir=ltr style="MARGIN-RIGHT: 0px">
  <DIV class=OutlookMessageHeader dir=ltr align=left><FONT face=Tahoma 
  size=2>-----Original Message-----<BR><B>From:</B> Marlon Mills 
  [mailto:[EMAIL PROTECTED]]<BR><B>Sent:</B> vrijdag 6 april 2001 
  4:27<BR><B>To:</B> [EMAIL PROTECTED]<BR><B>Subject:</B> 
  Checkpoint &amp; Micro I/A<BR><BR></FONT></DIV>
  <DIV><FONT face=Arial size=2>Hello all,</FONT></DIV>
  <DIV><FONT face=Arial size=2>I'm working with 2&nbsp;Micro I/As at ver 6.1 and 
  AW70 doing mainly sequence logic and Allen Bradley Flex I/O.</FONT></DIV>
  <DIV><FONT face=Arial size=2></FONT>&nbsp;</DIV>
  <DIV><FONT face=Arial size=2>Power losses and setpoint changes are occasional 
  and in order to save running settings&nbsp;a checkpoint is done before power 
  loss.&nbsp; Upon resumption of power and station startup, the system has 
  strange setpoints for example that were not there at the time of 
  checkpointing.</FONT></DIV>
  <DIV><FONT face=Arial size=2></FONT>&nbsp;</DIV>
  <DIV><FONT face=Arial size=2>Hints anyone ?</FONT></DIV>
  <DIV><FONT face=Arial size=2></FONT>&nbsp;</DIV>
  <DIV><FONT face=Arial size=2></FONT>&nbsp;</DIV>
  <DIV><FONT face=Arial size=2>Marlon 
Mills</FONT></DIV></BLOCKQUOTE></BODY></HTML>