Hi,
I have Secugen scanner, and want to help make it working
Bus 001 Device 004: ID 1162:0322 Secugen Corp.
After I add
{ .vendor = 0x1162, .product = 0x0322 },
line into fdu2000.c it recognizes device but prints error:
# pam_fprint_enroll
This program will enroll your finger, unconditionally overwriting any
selected print that was enrolled previously. If you want to continue,
press enter, otherwise hit Ctrl+C
Found device claimed by Secugen FDU 2000 driver
fdu2000:error [dev_init] could not init dev
fdu2000:error [dev_init] could not set alt intf 0/1: Invalid argument
fp:error [fp_dev_open] device initialisation failed, driver=fdu2000
Could not open device.
# dmesg -c
usb 1-3: selecting invalid altsetting 1
_______________________________________________
fprint mailing list
[email protected]