--On 11 May 2012 16:23 +0300 Alexander Motin <[email protected]> wrote:

I've committed patch to the HEAD branch:
http://svn.freebsd.org/changeset/base/235270

It should cleanly apply to 8/9-STABLE.

Hi,

I've applied this to 9-RELEASE (as it's what we've been doing all the testing on so far) - and indeed it does seem to fix the problem. I can now pull drives at random, and it survives. Inserting a new drive also kicks off a RAID rebuild.

Thanks,

-Karl
_______________________________________________
[email protected] mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-geom
To unsubscribe, send any mail to "[email protected]"

Reply via email to