On Tue, 2 Mar 2010 22:17:03 +0100 Bernd Walter <[email protected]> wrote:
>> On Tue, Mar 02, 2010 at 06:02:42PM +0200, Alexandr Rybalko wrote: >> > Hi, >> > >> > I making correct driver for SoC switch which is Pseudo PHY on bfe >> > interface. >> > Someone can point me correct way to fake PHY ID for make it possible auto >> > attach bfeswitch pseudo PHY driver? >> >> Has the switch an MDIO connection? Yes. >> I wrote the rtlswitch pseudo PHY driver for the RTL8305SC , which AFAIK still >> is the only one. >> The switch identifies without problem via identifiers, but it occupies >> multiple >> addresses and to avoid other drivers to claim the other IDs the rtlswitch >> driver claims all, but only attaches one time. My problem different, switch use one PHY address, but they (as I know) don`t provide identification. And I have to devices one on BCM5354 they have one bfe and one switch second on BCM5350 they have two bfe and one switch So I can`t only set hardcoded link bfe to bfeswitch. I need way for keeping auto probe and to know how fake switch id depend on outer info. >> >> ate0: <EMAC> mem 0xdffbc000-0xdffbffff irq 24 on atmelarm0 >> miibus0: <MII bus> on ate0 >> rlswitch0: <RTL8305SC 10/100 802.1q switch> PHY 0 on miibus0 >> rlswitch0: 100baseTX-FDX >> rlswitch1: <RTL8305SC 10/100 802.1q switch> PHY 1 on miibus0 >> rlswitch1: ignoring this PHY, non-zero instance >> device_attach: rlswitch1 attach returned 6 >> rlswitch2: <RTL8305SC 10/100 802.1q switch> PHY 2 on miibus0 >> rlswitch2: ignoring this PHY, non-zero instance >> device_attach: rlswitch2 attach returned 6 >> rlswitch3: <RTL8305SC 10/100 802.1q switch> PHY 3 on miibus0 >> rlswitch3: ignoring this PHY, non-zero instance >> device_attach: rlswitch3 attach returned 6 >> rlswitch4: <RTL8305SC 10/100 802.1q switch> PHY 4 on miibus0 >> rlswitch4: ignoring this PHY, non-zero instance >> device_attach: rlswitch4 attach returned 6 >> rlswitch5: <RTL8305SC 10/100 802.1q switch> PHY 5 on miibus0 >> rlswitch5: ignoring this PHY, non-zero instance >> device_attach: rlswitch5 attach returned 6 >> >> Beside from loocking strange it works fine this way. >> >> -- >> B.Walter <[email protected]> http://www.bwct.de >> Modbus/TCP Ethernet I/O Baugruppen, ARM basierte FreeBSD Rechner uvm. -- Рыбалко Александр Консультант D-Link Украина _______________________________________________ [email protected] mailing list http://lists.freebsd.org/mailman/listinfo/freebsd-hardware To unsubscribe, send any mail to "[email protected]"