Il 04/05/10 21:54, Xin LI ha scritto:
On Mon, Apr 5, 2010 at 8:24 AM, Andrea Venturoli<[email protected]>  wrote:
Hello.

Is the SAS controller in subject supported?
To what level?
Can it just run?
Is there management software available?
Can at least RAID status be checked?

I'd like to run a RAID5 on that.

I think it was LSI 1078 (mfi(4)?) ?  I don't have my hands on the
hardware though, if you have the hardware consider giving us a
feedback, thanks!

I've finally put my hands on this.
So far, so good (although the box is not in production yet).
I've noticed some delay at boot, although I cannot tell if this is mfi related.



Here's the requested feedback:

# dmesg|grep mfi
mfi0: <LSI MegaSAS 1078> port 0x3000-0x30ff mem 
0xb1c00000-0xb1c3ffff,0xb1c40000-0xb1c7ffff irq 24 at device 0.0 on pci2
mfi0: Megaraid SAS driver Ver 3.00
mfi0: 1772 (333483265s/0x0020/info) - Shutdown command received from host
mfi0: 1773 (boot + 3s/0x0020/info) - Firmware initialization started (PCI ID 
0060/1000/1006/8086)
mfi0: 1774 (boot + 3s/0x0020/info) - Firmware version 1.40.92-0746
mfi0: 1775 (boot + 3s/0x0020/info) - Board Revision
mfi0: 1776 (boot + 32s/0x0010/info) - Connector Int.Ports 0-3 (loc=2 
sasMux=0x0) is active
mfi0: 1777 (boot + 32s/0x0010/info) - Connector Int.Ports 4-7 (loc=2 
sasMux=0x1) is active
mfi0: 1778 (boot + 32s/0x0002/info) - Inserted: PD 11(e0xff/s17)
mfi0: 1779 (boot + 32s/0x0002/info) - Inserted: PD 11(e0xff/s17) Info: 
enclPd=ffff, scsiType=0, portMap=01, sasAddr=5000cca00f19fb45,0000000000000000
mfi0: 1780 (boot + 32s/0x0002/info) - Inserted: PD 12(e0xff/s18)
mfi0: 1781 (boot + 32s/0x0002/info) - Inserted: PD 12(e0xff/s18) Info: 
enclPd=ffff, scsiType=0, portMap=00, sasAddr=5000cca00f14a935,0000000000000000
mfi0: 1782 (boot + 32s/0x0002/info) - Inserted: PD 13(e0xff/s19)
mfi0: 1783 (boot + 32s/0x0002/info) - Inserted: PD 13(e0xff/s19) Info: 
enclPd=ffff, scsiType=0, portMap=03, sasAddr=5000cca00f187d45,0000000000000000
mfi0: 1784 (boot + 32s/0x0002/info) - Inserted: PD 14(e0xff/s20)
mfi0: 1785 (boot + 32s/0x0002/info) - Inserted: PD 14(e0xff/s20) Info: 
enclPd=ffff, scsiType=0, portMap=02, sasAddr=5000cca00f15807d,0000000000000000
mfi0: 1786 (333483308s/0x0020/info) - Time established as 07/26/10 18:15:08; 
(35 seconds since power on)
mfi0: 1787 (boot + 3s/0x0020/info) - Firmware initialization started (PCI ID 
0060/1000/1006/8086)
mfi0: 1788 (boot + 3s/0x0020/info) - Firmware version 1.40.92-0746
mfi0: 1789 (boot + 3s/0x0020/info) - Board Revision
mfi0: 1790 (boot + 32s/0x0010/info) - Connector Int.Ports 0-3 (loc=2 
sasMux=0x0) is active
mfi0: 1791 (boot + 32s/0x0010/info) - Connector Int.Ports 4-7 (loc=2 
sasMux=0x1) is active
mfi0: 1792 (boot + 32s/0x0002/info) - Inserted: PD 11(e0xff/s17)
mfi0: 1793 (boot + 32s/0x0002/info) - Inserted: PD 11(e0xff/s17) Info: 
enclPd=ffff, scsiType=0, portMap=01, sasAddr=5000cca00f19fb45,0000000000000000
mfi0: 1794 (boot + 32s/0x0002/info) - Inserted: PD 12(e0xff/s18)
mfi0: 1795 (boot + 32s/0x0002/info) - Inserted: PD 12(e0xff/s18) Info: 
enclPd=ffff, scsiType=0, portMap=00, sasAddr=5000cca00f14a935,0000000000000000
mfi0: 1796 (boot + 32s/0x0002/info) - Inserted: PD 13(e0xff/s19)
mfi0: 1797 (boot + 32s/0x0002/info) - Inserted: PD 13(e0xff/s19) Info: 
enclPd=ffff, scsiType=0, portMap=03, sasAddr=5000cca00f187d45,0000000000000000
mfi0: 1798 (boot + 32s/0x0002/info) - Inserted: PD 14(e0xff/s20)
mfi0: 1799 (boot + 32s/0x0002/info) - Inserted: PD 14(e0xff/s20) Info: 
enclPd=ffff, scsiType=0, portMap=02, sasAddr=5000cca00f15807d,0000000000000000
mfi0: 1800 (333483496s/0x0020/info) - Time established as 07/26/10 18:18:16; 
(35 seconds since power on)
mfi0: 1801 (boot + 3s/0x0020/info) - Firmware initialization started (PCI ID 
0060/1000/1006/8086)
mfi0: 1802 (boot + 3s/0x0020/info) - Firmware version 1.40.92-0746
mfi0: 1803 (boot + 3s/0x0020/info) - Board Revision
mfi0: 1804 (boot + 32s/0x0010/info) - Connector Int.Ports 0-3 (loc=2 
sasMux=0x0) is active
mfi0: 1805 (boot + 32s/0x0010/info) - Connector Int.Ports 4-7 (loc=2 
sasMux=0x1) is active
mfi0: 1806 (boot + 32s/0x0002/info) - Inserted: PD 11(e0xff/s17)
mfi0: 1807 (boot + 32s/0x0002/info) - Inserted: PD 11(e0xff/s17) Info: 
enclPd=ffff, scsiType=0, portMap=01, sasAddr=5000cca00f19fb45,0000000000000000
mfi0: 1808 (boot + 32s/0x0002/info) - Inserted: PD 12(e0xff/s18)
mfi0: 1809 (boot + 32s/0x0002/info) - Inserted: PD 12(e0xff/s18) Info: 
enclPd=ffff, scsiType=0, portMap=00, sasAddr=5000cca00f14a935,0000000000000000
mfi0: 1810 (boot + 32s/0x0002/info) - Inserted: PD 13(e0xff/s19)
mfi0: 1811 (boot + 32s/0x0002/info) - Inserted: PD 13(e0xff/s19) Info: 
enclPd=ffff, scsiType=0, portMap=03, sasAddr=5000cca00f187d45,0000000000000000
mfi0: 1812 (boot + 32s/0x0002/info) - Inserted: PD 14(e0xff/s20)
mfi0: 1813 (boot + 32s/0x0002/info) - Inserted: PD 14(e0xff/s20) Info: 
enclPd=ffff, scsiType=0, portMap=02, sasAddr=5000cca00f15807d,0000000000000000
mfi0: [ITHREAD]
mfi0: 1814 (333483629s/0x0020/info) - Time established as 07/26/10 18:20:29; 
(35 seconds since power on)
mfid0: <MFI Logical Disk> on mfi0
mfid0: 1284597MB (2630854656 sectors) RAID volume '' is optimal

Of course it's detected as a generic LSI MegaSAS 1078, since the specific PCI IDs are not there. No problem here: I'm reporting them just in case you want to include them in an updated driver version.

# pciconf -lv
> ...
m...@pci0:2:0:0:        class=0x010400 card=0x10068086 chip=0x00601000 rev=0x04 
hdr=0x00
    vendor     = 'LSI Logic (Was: Symbios Logic, NCR)'
    device     = 'SAS1078 PCI-X Fusion-MPT SAS'
    class      = mass storage
    subclass   = RAID
> ...

# mfiutil show adapter
mfi0 Adapter:
    Product Name: Intel(R) RAID Controller SRCSASJV
   Serial Number: P054824609
        Firmware: 11.0.1-0022
     RAID Levels: JBOD, RAID0, RAID1, RAID5, RAID6, RAID10, RAID50
  Battery Backup: not present
           NVRAM: 32K
  Onboard Memory: 512M
  Minimum Stripe: 8K
  Maximum Stripe: 1M

# mfiutil show firmware
mfi0 Firmware Package Version: 11.0.1-0022
mfi0 Firmware Images:
Name  Version            Date         Time      Status
APP   1.40.92-0746       Nov  3 2009  12:10:24  active
BIOS  2.07.00            Aug 26 2009  15:05:19  active
BCON  2.2-19-e_10-Rel    Jun 30 2009  11:59:33  active
PCLI  01.40-010:#%00008  Aug 21 2009  00:10:02  active
BTBL  1.00.00.01-0011    Nov 27 2007  18:29:20  active


I really like mfiutil. Any chance it will be merged into 7.x?


If you need other data, just ask :-)

 bye & Thanks
        av.
_______________________________________________
[email protected] mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-hardware
To unsubscribe, send any mail to "[email protected]"

Reply via email to