Hi, I have the following setup:
box1 box2 box3 box4 xl0 xl0 xl0 ste0/ste1/ste2/ste3 -> fec0 1.1.1.1 1.1.1.2 1.1.1.3 1.1.1.4 | | | | | | | | | | | | | | ======================================== cisco catalyst switch Hosts box1,2,3,4 are running stock fbsd -current. box4 has a 4-port ethernet card (forgot brand, think d-link) recognized by the ste driver, without IP addresses. I then configure bonding on the ste0..3 interfaces with ng_fec, which gives me a fec0 interface. I then configure fec0 with set_mode_mac and with IP address 1.1.1.4. The switch is configured to perform etherchannel on the 4 ports connected to the ste0..4 interfaces. Load "balancing" is done on a per source MAC address. Problem is when I ping box4 from the other boxes. I get a reply only for ping from box1. I then ran tcpdump on the 4 ste interfaces. Things become to get interesting. If tcpdump is ran in non-promiscuos mode (-p option), only ping (and ARP) from box1 goes thru, as if I wasn't running tcpdump at all. If on the other hand tcpdump is ran in promiscuos mode, then all the pings go thru as expected. Am I doing something wrong in configuring the fec0 interface or is this a known problem? I think I don't need to add any IP address on the ste interfaces themselves. thanks marco -- He who receives an idea from me, receives instruction himself without lessening mine; as he who lights his taper at mine, receives light without darkening me. -- Thomas Jefferson _______________________________________________ [email protected] mailing list http://lists.freebsd.org/mailman/listinfo/freebsd-net To unsubscribe, send any mail to "[EMAIL PROTECTED]"