Monitoring a tcpdump between two systems, a FreeBSD 9.1 system has the 
following interface:

msk0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500
        
options=c011b<RXCSUM,TXCSUM,VLAN_MTU,VLAN_HWTAGGING,TSO4,VLAN_HWTSO,LINKSTATE>
        ether 00:11:2f:2a:c7:03
        inet 10.0.1.199 netmask 0xffffff00 broadcast 10.0.1.255
        inet6 fe80::211:2fff:fe2a:c703%msk0 prefixlen 64 scopeid 0x1 
        nd6 options=29<PERFORMNUD,IFDISABLED,AUTO_LINKLOCAL>
        media: Ethernet autoselect (100baseTX 
<full-duplex,flowcontrol,rxpause,txpause>)
        status: active


It sent the following packet:  (data content abbreviated)

02:14:42.081617 IP 10.0.1.199.443 > 10.0.1.2.61258: Flags [P.], seq 930:4876, 
ack 846, win 1040, options [nop,nop,TS val 401838072 ecr 920110183], length 3946
        0x0000:  4500 0f9e ea89 4000 4006 2a08 0a00 01c7  E.....@.@.*.....
        0x0010:  0a00 0102 01bb ef4a ece1 680b ae37 1bbc  .......J..h..7..
        0x0020:  8018 0410 3407 0000 0101 080a 17f3 8ff8  ....4...…….


The indicated packet length is 3946 and the load of data shown is that size.  
The MTU on both interfaces is 1500.  The receiving system received 3 packets.  
There is a router and switch between them.  One of them fragmented that packet. 
This is part of a SSL/TLS exchange and one side or the other is hanging on this 
and just dropping the connection.  I suspect the packet size is the issue.  
ssldump complains about the packet too and stops monitoring.  Could this 
possibly be related to the hardware checksums?