I'll second that. I have the 3ware two port model and it seems to have "burped" and decided one of the disks was dead. I went to the management interface (web-only) and removed/added the "bad" drive and then rebuilt the mirror. Performance was fine during the rebuild.
Now why the one drive went "bad" is a question I cannot answer... Supposedly the newest firmware supports SMART, but I don't think the FreeBSD driver nor the 3ware web interface do anything with that data.
It does for me. Here is an example warning I get on bad drives. It also logs it to kern via syslog.
SMART Threshold Exceeded condition detected on port 1 on controller ID:0. Check drive for media errors. (0xf)
This was from a bad Fujitsu.
---Mike
_______________________________________________ [EMAIL PROTECTED] mailing list http://lists.freebsd.org/mailman/listinfo/freebsd-stable To unsubscribe, send any mail to "[EMAIL PROTECTED]"