> > On Wed, Apr 19, 2006 at 04:15:10PM +0400, Yuriy Tsibizov wrote: > > > I run a 6.1-RC (as of Apr, 14th) and after a day nothing > > can be sent from em interface. > > > > > > It is a filtering+accounting bridge-on-a-stick, with em interface > > > connected to 3Com Switch 4200 100Mbit (not Gbit) port > with 4 tagged > > > vlans on it: > > > > > > Polling was not used (I'll try to work with polling > enabled on em0). > > > > > > ALTQ is not configured, pf has all block rules logged and I > > can't see anything relevant logged to pflog. > > > > > > Traffic is received (I can see pairs of OSPF HELO > messages from ISP > > > router logged on pflog0 exactly every 10 seconds), but it > looks like > > > nothing can be sent. > > > > A bridge on a stick only works under certian conditions, > > mainly support > > by the switch its connected to. Its obviously working for you for a > > period of time so thats probably ok. > > > > Make sure that you dont use scrubbing with pf as the bridge doesn't > > handle the fragment reassembly at the moment. > I had it, and will try to work without it. One question - if pf was the cause, should it recover when I disable pf? As I remeber, the box was still silent on vlan interfaces, when pf was disabled with "/etc/rc.d/pf stop".
Yuriy _______________________________________________ [email protected] mailing list http://lists.freebsd.org/mailman/listinfo/freebsd-stable To unsubscribe, send any mail to "[EMAIL PROTECTED]"