Hi Clay,

Sounds like power problem to me. Perhaps there is not enough power for the drive.

I tried to unplug all devices (cd-roms, 2nd disk, ...), and it still appears :-/

Best advice I could give is not to use Maxtor. They have known problems with many models and in my opinion are not good hard drives.

I think I'm okay with that !!!

Here's the result from
        smartctl -a -t long /dev/ad4

If someone can find somthing wrong in it ...

Thanks
--
Ivan Kurzweg
Web : http://www.kurzweg.info


BOFH excuse #14: sounds like a Windows problem, try calling Microsoft support
smartctl version 5.37 [i386-portbld-freebsd6.1] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Model Family:     Maxtor DiamondMax 10 family (SATA/300)
Device Model:     Maxtor 6V160E0
Serial Number:    V39SA0AG
Firmware Version: VA111900
User Capacity:    160,041,885,696 bytes
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 0
Local Time is:    Fri Jan 19 08:33:31 2007 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x80) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (  41) The self-test routine was interrupted
                                        by the host with a hard or soft reset.
Total time to complete Offline 
data collection:                 (1382) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  71) minutes.

SMART Attributes Data Structure revision number: 32
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  3 Spin_Up_Time            0x0027   214   209   063    Pre-fail  Always       
-       7209
  4 Start_Stop_Count        0x0032   253   253   000    Old_age   Always       
-       46
  5 Reallocated_Sector_Ct   0x0033   253   253   063    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000a   253   252   000    Old_age   Always       
-       0
  8 Seek_Time_Performance   0x0027   239   239   187    Pre-fail  Always       
-       36113
  9 Power_On_Hours          0x0032   253   253   000    Old_age   Always       
-       153
 10 Spin_Retry_Count        0x002b   253   252   157    Pre-fail  Always       
-       0
 11 Calibration_Retry_Count 0x002b   253   252   223    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   253   253   000    Old_age   Always       
-       117
189 Unknown_Attribute       0x003a   100   100   000    Old_age   Always       
-       0
190 Temperature_Celsius     0x0022   051   044   000    Old_age   Always       
-       825294897
192 Power-Off_Retract_Count 0x0032   253   253   000    Old_age   Always       
-       0
193 Load_Cycle_Count        0x0032   253   253   000    Old_age   Always       
-       0
194 Temperature_Celsius     0x0032   041   253   000    Old_age   Always       
-       49
195 Hardware_ECC_Recovered  0x000a   253   252   000    Old_age   Always       
-       726
196 Reallocated_Event_Count 0x0008   253   253   000    Old_age   Offline      
-       0
197 Current_Pending_Sector  0x0008   253   253   000    Old_age   Offline      
-       0
198 Offline_Uncorrectable   0x0008   253   253   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0008   199   199   000    Old_age   Offline      
-       0
200 Multi_Zone_Error_Rate   0x000a   253   252   000    Old_age   Always       
-       0
201 Soft_Read_Error_Rate    0x000a   253   252   000    Old_age   Always       
-       0
202 TA_Increase_Count       0x000a   253   252   000    Old_age   Always       
-       0
203 Run_Out_Cancel          0x000b   253   252   180    Pre-fail  Always       
-       0
204 Shock_Count_Write_Opern 0x000a   253   252   000    Old_age   Always       
-       0
205 Shock_Rate_Write_Opern  0x000a   253   252   000    Old_age   Always       
-       0
207 Spin_High_Current       0x002a   253   252   000    Old_age   Always       
-       0
208 Spin_Buzz               0x002a   253   252   000    Old_age   Always       
-       0
210 Unknown_Attribute       0x0032   253   252   000    Old_age   Always       
-       0
211 Unknown_Attribute       0x0032   253   252   000    Old_age   Always       
-       0
212 Unknown_Attribute       0x0032   253   252   000    Old_age   Always       
-       0

SMART Error Log Version: 1
ATA Error Count: 2
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 2 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
  When the command that caused the error occurred, the device was in an unknown 
state.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 45 00 00 00 a0

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ec 03 46 00 00 00 a0 00      00:00:48.403  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      00:00:48.346  SET FEATURES [Set transfer mode]
  ec 00 01 01 00 00 a0 00      00:00:48.331  IDENTIFY DEVICE
  81 04 10 04 01 32 e0 00      00:00:48.171  [VENDOR SPECIFIC]
  c6 00 10 04 01 32 e0 00      00:00:36.693  SET MULTIPLE MODE

Error 1 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
  When the command that caused the error occurred, the device was in an unknown 
state.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 46 00 00 00 a0  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ef 03 46 00 00 00 a0 00      00:00:48.346  SET FEATURES [Set transfer mode]
  ec 00 01 01 00 00 a0 00      00:00:48.331  IDENTIFY DEVICE
  81 04 10 04 01 32 e0 00      00:00:48.171  [VENDOR SPECIFIC]
  c6 00 10 04 01 32 e0 00      00:00:36.693  SET MULTIPLE MODE
  ef 03 46 00 00 e0 e0 00      00:00:36.692  SET FEATURES [Set transfer mode]

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Extended self-test routine immediately in 
off-line mode".
Drive command "Execute SMART Extended self-test routine immediately in off-line 
mode" successful.
Testing has begun.
Please wait 71 minutes for test to complete.
Test will complete after Fri Jan 19 09:44:31 2007

Use smartctl -X to abort test.
_______________________________________________
[email protected] mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-stable
To unsubscribe, send any mail to "[EMAIL PROTECTED]"

Reply via email to