Hi all,
I need some help to read Temperature sensors on a Dell PowerEdge R410
model name : Intel(R) Xeon(R) CPU E5620 @ 2.40GHz
# uname -a
Linux pc-xyz 2.6.18-238.1.1.el5 #1 SMP Wed Jan 19 11:06:36 CET 2011
x86_64 x86_64 x86_64 GNU/Linux
If I try (from another host with freeipmi 1.06.beta0 installed) the
following command:
# ipmi-sensors -V
ipmi-sensors - 1.0.6.beta0
# ipmi-sensors -h pc-xyz -u user -p passw | grep -i temp
1 | Temp | Temperature | N/A | C | N/A
2 | Temp | Temperature | N/A | C | N/A
3 | Temp | Temperature | N/A | C | N/A
4 | Temp | Temperature | N/A | C | N/A
5 | Ambient Temp | Temperature | N/A | C | N/A
6 | Ambient Temp | Temperature | N/A | C | N/A
7 | Temp | Temperature | N/A | C | N/A
8 | Temp | Temperature | N/A | C | N/A
9 | Temp | Temperature | N/A | C | N/A
10 | Ambient Temp | Temperature | 21.00 | C |
'OK'
11 | Planar Temp | Temperature | N/A | C | N/A
65 | CPU Temp Interf | Temperature | N/A | N/A | N/A
110 | Mem Overtemp | Memory | N/A | N/A | N/A
ie: only ambient temperature is available, while if I use ipmitool:
# ipmitool -H pc-xyz -U user -P passw sdr type temperature
Temp | 01h | ok | 3.1 | -57 degrees C
Temp | 02h | ok | 3.2 | -63 degrees C
Temp | 05h | ok | 10.1 | 19 degrees C
Ambient Temp | 07h | ok | 10.1 | 24 degrees C
Temp | 06h | ok | 10.2 | 30 degrees C
Ambient Temp | 08h | ok | 10.2 | 27 degrees C
Ambient Temp | 0Eh | ok | 7.1 | 18 degrees C
Planar Temp | 0Fh | ok | 7.1 | 35 degrees C
IOH THERMTRIP | 5Dh | ns | 7.1 | Disabled
CPU Temp Interf | 76h | ns | 7.1 | Disabled
Temp | 0Ah | ok | 8.1 | 26 degrees C
Temp | 0Bh | ok | 8.1 | 23 degrees C
Temp | 0Ch | unc | 8.1 | 44 degrees C
I obtain much more info.
What am I doing wrong ??
thank you very much for your help!
ciao
Franco