Hi Andrew, Thanks for the report. Since this is a OEM specific command, there is a good chance this just isn't supported on your motherboard. There is no way to know what Supermicro may have meant with the 0x83 error code.
Al On Thu, 2020-08-20 at 18:28 -0400, Andrew Orme wrote: > admin@server:~# ipmi-oem --debug Supermicro get-power-supply-status 1 > ===================================================== > Master Write Read Request > ===================================================== > KCS Header: > ------------ > [ 0h] = lun[ 2b] > [ 6h] = net_fn[ 6b] > IPMI Command Data: > ------------------ > [ 52h] = cmd[ 8b] > [ BYTE ARRAY ... ] = raw_data[ 4B] > [ 07h 70h 01h 0Ch ] > ===================================================== > Master Write Read Response > ===================================================== > KCS Header: > ------------ > [ 0h] = lun[ 2b] > [ 7h] = net_fn[ 6b] > IPMI Command Data: > ------------------ > [ 52h] = cmd[ 8b] > [ BYTE ARRAY ... ] = raw_data[ 1B] > [ 83h ] > Supermicro:get-power-supply-status failed: No error message found for > command 52h, network function 06h, and completion code 83h. Please > report to <freeipmi-devel@gnu.org> > > admin@server:~# dmidecode -t 39 | grep 'Name' > Name: To Be Filled By O.E.M. > Name: To Be Filled By O.E.M. > > admin@server:~# dmidecode -t 39 > # dmidecode 2.12 > SMBIOS 2.8 present. > > Handle 0x0018, DMI type 39, 22 bytes > System Power Supply > Power Unit Group: 1 > Location: PSU1 > Name: To Be Filled By O.E.M. > Manufacturer: To Be Filled By O.E.M. > Serial Number: To Be Filled By O.E.M. > Asset Tag: To Be Filled By O.E.M. > Model Part Number: To Be Filled By O.E.M. > Revision: To Be Filled By O.E.M. > Max Power Capacity: Unknown > Status: Not Present > Type: Switching > Input Voltage Range Switching: Auto-switch > Plugged: Yes > Hot Replaceable: No > > Handle 0x0019, DMI type 39, 22 bytes > System Power Supply > Power Unit Group: 2 > Location: PSU2 > Name: To Be Filled By O.E.M. > Manufacturer: To Be Filled By O.E.M. > Serial Number: To Be Filled By O.E.M. > Asset Tag: To Be Filled By O.E.M. > Model Part Number: To Be Filled By O.E.M. > Revision: To Be Filled By O.E.M. > Max Power Capacity: Unknown > Status: Not Present > Type: Switching > Input Voltage Range Switching: Auto-switch > Plugged: Yes > Hot Replaceable: No