Hi Ragha, > Lookinginto the problem I've found that on the blades no process is > running on the port 623 (which is the default port used by rmcpping).
No process is required to run w/ port 623 since rmcpping communicates with the service processor on a motherboard. If the service processor runs on stand-by power (many motherboards do, yours may not necessarily) that means you can even rmcpping a machine when it is powered off. > In that case how is the communication b/w BMC and MCs is done?? > Is it through the IPMB Bus?? i.e., does BMC and MCs on the blades > never use Ethernet to communicate (Specifically MCs not the processes like > openhpiapps running on blades)?? I've seen some bladed solutions that only allow remote management with the blade manager, and not with an individual blade. It is the responsibility of the blade manager to then communicate with each blade to do the management activity (power control, sensor retrieval, etc.). I don't know your specific hardware, so I can't really say about your particular hardware. I *think* communication is done through the ICMB bus to the blades, but my terminology understanding may be wrong here. However, I've also seen it done through serial. So it's just up to the implementation. Al -- Albert Chu [EMAIL PROTECTED] 925-422-5311 Computer Scientist High Performance Systems Division Lawrence Livermore National Laboratory ----- Original Message ----- From: Raghavendra G <[EMAIL PROTECTED]> Date: Thursday, May 25, 2006 10:00 pm Subject: [Freeipmi-users] Some basic questions > Hi all, > We have an ATCA chassis with Schroff shelf manager (BMC). The > chassis has 4 > blades each having an MC. I am able to rmcpping the Shelf > Manager(BMC) from > any of the blades. But I am not able to rmcpping b/w the blades. > Lookinginto the problem I've found that on the blades no process is > running on the > port 623 (which is the default port used by rmcpping). > > Is it that only the Shelf Manager can reply to rmcppings but not > the MCs on > the blades? In that case how is the communication b/w BMC and MCs > is done?? > Is it through the IPMB Bus?? i.e., does BMC and MCs on the blades > never use > Ethernet to communicate (Specifically MCs not the processes like > openhpiapps running on blades)?? > > Regards, > -- > > Raghavendra G > Software Engineer, > Clovis Solutions, Bangalore > +91 9880213025 > _______________________________________________ > Freeipmi-users mailing list > [email protected] > http://lists.gnu.org/mailman/listinfo/freeipmi-users > _______________________________________________ Freeipmi-users mailing list [email protected] http://lists.gnu.org/mailman/listinfo/freeipmi-users