I want to monitor my Fujitsu servers with the check-ipmi-sensor plugin (v2) for Nagios. It requires the ipmimonitoring tool from freeipmi.
I tried the freeipmi version 0.5.1 shipped with CentOS 5.6. OK, it is really old, but the ipmi-sensors works fine. But the command "ipmimonitoring" doesn't work - it returns a SDR cache error: [root@bart ~]# ipmimonitoring -h 60.18.18.1 -l user ipmi_monitoring_sensor_readings_by_record_id: internal error If I use the --debug switch, the additional info is: (ipmi_monitoring_sdr_cache.c, _ipmi_monitoring_sdr_cache_retrieve, 537): ipmi_sdr_cache_complete: incomplete number of records written OK, I assume there will be no support for this old version, neither by the freeipmi developers or Redhat/CentOS. Next I tried the freeipmi version 0.7.16 shipped with CentOS 6. But ipmi-sensors or ipmimonitoring doesn't show any SDR values, it returns only NA. That's why I have compiled the newest freeipmi 1.0.6 on CentOS 5.6. But, surprise, ipmi-sensors doesn't show any SDR values, it returns only N/A: (0)omo@maggie: /home/a18/omo/rpmbuild/BUILD/freeipmi-1.0.6/ipmi-sensors/src $su -c "./ipmi-sensors -h 18.18.18.2 -l user" Password: ID | Name | Type | Reading | Units | Event 0 | Systemboard | Temperature | N/A | C | N/A 64 | CPU0 | Temperature | N/A | C | N/A 128 | CPU1 | Temperature | N/A | C | N/A 192 | Ambient | Temperature | N/A | C | N/A 256 | PSU | Temperature | N/A | C | N/A 320 | PSU FanControl | OEM Reserved | N/A | C | N/A 384 | PSU Power | Current | N/A | W | N/A 448 | Main +12V | Voltage | N/A | V | N/A 512 | Main -12V | Voltage | N/A | V | N/A 576 | Main +5V | Voltage | N/A | V | N/A 640 | Main 3.3V | Voltage | N/A | V | N/A 704 | Battery +3V | Voltage | N/A | V | N/A 768 | Main 2.5V | Voltage | N/A | V | N/A 832 | Stdby +3.3V | Voltage | N/A | V | N/A 896 | SSTL_Term | Voltage | N/A | V | N/A 960 | Main +1.5V | Voltage | N/A | V | N/A 1024 | VGA +2.5V | Voltage | N/A | V | N/A 1088 | Lan +1.2V | Voltage | N/A | V | N/A 1152 | Lan +2.5V | Voltage | N/A | V | N/A 1216 | SCSI +1.8V | Voltage | N/A | V | N/A 1280 | BMC +2.5V | Voltage | N/A | V | N/A 1344 | FAN SYS0 | Fan | N/A | RPM | N/A 1408 | FAN SYS1 | Fan | N/A | RPM | N/A 1472 | FAN SYS2 | Fan | N/A | RPM | N/A 1536 | FAN PS0 | Fan | N/A | RPM | N/A 1600 | FAN SYS3 | Fan | N/A | RPM | N/A 1664 | FAN SYS4 | Fan | N/A | RPM | N/A 1728 | FAN SYS5 | Fan | N/A | RPM | N/A 1792 | FAN PS1 | Fan | N/A | RPM | N/A 1856 | FAN CPU0 | Fan | N/A | RPM | N/A 1920 | FAN CPU1 | Fan | N/A | RPM | N/A 1984 | SEL Level | Monitor ASIC/IC | N/A | % | N/A 2048 | CPU0 PRSNT | Entity Presence | N/A | N/A | N/A 2096 | CPU0 | Processor | N/A | N/A | N/A 2144 | CPU1 PRSNT | Entity Presence | N/A | N/A | N/A 2192 | CPU1 | Processor | N/A | N/A | N/A 2240 | PS0 PRSNT | Entity Presence | N/A | N/A | N/A 2288 | PS1 PRSNT | Entity Presence | N/A | N/A | N/A 2336 | FAN SYS0 PRSNT | Entity Presence | N/A | N/A | N/A 2384 | FAN SYS1 PRSNT | Entity Presence | N/A | N/A | N/A 2432 | FAN SYS2 PRSNT | Entity Presence | N/A | N/A | N/A 2480 | FAN PS0 PRSNT | Entity Presence | N/A | N/A | N/A 2528 | FAN SYS3 PRSNT | Entity Presence | N/A | N/A | N/A 2576 | FAN SYS4 PRSNT | Entity Presence | N/A | N/A | N/A 2624 | FAN SYS5 PRSNT | Entity Presence | N/A | N/A | N/A 2672 | FAN PS1 PRSNT | Entity Presence | N/A | N/A | N/A 2720 | FAN SYS0 STAT | OEM Reserved | N/A | N/A | N/A 2768 | FAN SYS1 STAT | OEM Reserved | N/A | N/A | N/A 2816 | FAN SYS2 STAT | OEM Reserved | N/A | N/A | N/A 2864 | FAN PS0 STAT | OEM Reserved | N/A | N/A | N/A 2912 | FAN SYS3 STAT | OEM Reserved | N/A | N/A | N/A 2960 | FAN SYS4 STAT | OEM Reserved | N/A | N/A | N/A 3008 | FAN SYS5 STAT | OEM Reserved | N/A | N/A | N/A 3056 | FAN PS1 STAT | OEM Reserved | N/A | N/A | N/A 3104 | PS0 STAT | OEM Reserved | N/A | N/A | N/A 3152 | PS1 STAT | OEM Reserved | N/A | N/A | N/A 3200 | FAN CPU0 STAT | OEM Reserved | N/A | N/A | N/A 3248 | FAN CPU1 STAT | OEM Reserved | N/A | N/A | N/A 3296 | ACPI Power State | System ACPI Power State | N/A | N/A | N/A 3344 | Watchdog | Watchdog 2 | N/A | N/A | N/A 3392 | PSU RED PRSNT | Entity Presence | N/A | N/A | N/A 3440 | PSU RED STAT | OEM Reserved | N/A | N/A | N/A 3488 | PSU status | Power Unit | N/A | N/A | N/A 3536 | BMC request | OEM Reserved | N/A | N/A | N/A 4736 | System Mgmt SW | OEM Reserved | N/A | N/A | N/A 4784 | System BIOS | OEM Reserved | N/A | N/A | N/A 4832 | BMC | OEM Reserved | N/A | N/A | N/A (0)omo@maggie: /home/a18/omo/rpmbuild/BUILD/freeipmi-1.0.6/ipmi-sensors/src $su -c "./ipmi-sensors -h 18.18.18.2 -l user -s 0 -v" Password: Record ID: 0 ID String: Systemboard Sensor Type: Temperature (1h) Sensor Number: 1 IPMB Slave Address: 12h Sensor Owner ID: 24h Sensor Owner LUN: 0h Channel Number: 0h Entity ID: system board (7) Entity Instance: 0 Entity Instance Type: Physical Entity Event/Reading Type Code: 1h Sensor Min. Reading: -128.000000 C Sensor Max. Reading: 127.000000 C Normal Min.: N/A Normal Max.: N/A Nominal Reading: N/A Sensor Reading: N/A Sensor Event: N/A (0)omo@maggie: /home/a18/omo/rpmbuild/BUILD/freeipmi-1.0.6/ipmi-sensors/src $ Which information should I provide to track the bug? Kind regards, omo _______________________________________________ Freeipmi-users mailing list [email protected] https://lists.gnu.org/mailman/listinfo/freeipmi-users