> As you can see, sensor 36 and 48 are duplicated. IMHO that shouldn't > happen. I guess it's something Dell specific.
A number of Dell motherboards have this behavior. Dell lists multiple sensors by the same device name and expects the user software to "construct" a more usable sensor name using other information on the system. In FreeIPMI, I implement this as an option called --entity-sensor-names. It'd be interesting to see if this works for you. > Is there anything I could do to help to get that fixed? Like > offering additional > information. It'd be interesting to see the debug output (--debug). Please limit it to the record ids 36 & 48 by specifying -r 36,48. Al > Hi guys, > > there are duplicates on the mentioned system: > > # /usr/sbin/ipmi-sensors -h 10.0.0.178 --config-file > /etc/icinga/ipmi.cfg --quiet-cache --sdr-cache-recreate --interpret-oem-data > --output-sensor-state --ignore-not-available-sensors > ID | Name | Type | State | > Reading | Units | Event > 7 | Ambient Temp | Temperature | Nominal | 25.00 > | C | 'OK' > 9 | CMOS Battery | Battery | Nominal | N/A > | N/A | 'OK' > 11 | VCORE PG | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 12 | CPU1 0.75 VTT PG | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 13 | 1.8V AUX PG | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 14 | PS PG | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 15 | Riser2 5V PG | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 16 | Riser1 5V PG | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 17 | CPU1 MEM FAIL | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 18 | CPU1 VTT FAIL | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 19 | 1.05V AUX PG | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 20 | 1.8V PLL CPU1 PG | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 21 | 1.2V LOM FAIL | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 22 | 1.2V AUX FAIL | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 23 | 1.05V PG | Voltage | Nominal | N/A > | N/A | 'State Deasserted' > 24 | FAN MOD 1A RPM | Fan | Nominal | > 5880.00 | RPM | 'OK' > 25 | FAN MOD 1B RPM | Fan | Nominal | > 4800.00 | RPM | 'OK' > 26 | FAN MOD 2A RPM | Fan | Nominal | > 5880.00 | RPM | 'OK' > 27 | FAN MOD 2B RPM | Fan | Nominal | > 4800.00 | RPM | 'OK' > 28 | FAN MOD 3A RPM | Fan | Nominal | > 4560.00 | RPM | 'OK' > 29 | FAN MOD 3B RPM | Fan | Nominal | > 3360.00 | RPM | 'OK' > 30 | FAN MOD 4A RPM | Fan | Nominal | > 5040.00 | RPM | 'OK' > 31 | FAN MOD 4B RPM | Fan | Nominal | > 3480.00 | RPM | 'OK' > 32 | FAN MOD 5A RPM | Fan | Nominal | > 5040.00 | RPM | 'OK' > 33 | FAN MOD 5B RPM | Fan | Nominal | > 3480.00 | RPM | 'OK' > 34 | Presence | Entity Presence | Nominal | N/A > | N/A | 'Entity Present' > 35 | Heatsink Pres | Entity Presence | Nominal | N/A > | N/A | 'Entity Present' > 36 | iDRAC6 Ent Pres | Entity Presence | Critical | N/A > | N/A | 'Entity Absent' > 37 | Presence | Entity Presence | Nominal | N/A > | N/A | 'Entity Present' > 38 | Presence | Entity Presence | Nominal | N/A > | N/A | 'Entity Present' > 39 | Presence | Entity Presence | Nominal | N/A > | N/A | 'Entity Present' > 40 | USB Cable Pres | Entity Presence | Nominal | N/A > | N/A | 'Entity Present' > 41 | Riser2 Pres | Entity Presence | Nominal | N/A > | N/A | 'Entity Present' > 42 | Riser1 Pres | Entity Presence | Nominal | N/A > | N/A | 'Entity Present' > 44 | Status | Processor | Nominal | N/A > | N/A | 'Processor Presence detected' > 45 | Status | Power Supply | Nominal | N/A > | N/A | 'Presence detected' > 46 | Status | Power Supply | Nominal | N/A > | N/A | 'Presence detected' > 47 | Status | Cable/Interconnect | Nominal | N/A > | N/A | 'Cable/Interconnect is connected' > 48 | iDRAC6 Ent Pres | Entity Presence | Critical | N/A > | N/A | 'Entity Absent' > 49 | OS Watchdog | Watchdog 2 | Nominal | N/A > | N/A | 'OK' > 51 | Intrusion | Physical Security | Nominal | N/A > | N/A | 'OK' > 52 | PS Redundancy | Power Supply | Nominal | N/A > | N/A | 'Fully Redundant' > 53 | Fan Redundancy | Fan | Nominal | N/A > | N/A | 'Fully Redundant' > 56 | Drive | Drive Slot | Nominal | N/A > | N/A | 'Drive Presence' > 57 | Cable SAS A | Cable/Interconnect | Nominal | N/A > | N/A | 'Cable/Interconnect is connected' > 58 | Current 1 | Current | Nominal | 0.48 > | A | 'OK' > 59 | Current 2 | Current | Nominal | 0.48 > | A | 'OK' > 60 | Voltage 1 | Voltage | Nominal | 122.00 > | V | 'OK' > 61 | Voltage 2 | Voltage | Nominal | 120.00 > | V | 'OK' > 62 | System Level | Current | Nominal | 140.00 > | W | 'OK' > 63 | Power Optimized | OEM Reserved | Nominal | N/A > | N/A | 'Good' > 65 | DKM Status | OEM Reserved | N/A | N/A > | N/A | 'OEM Event = 0000h' > > As you can see, sensor 36 and 48 are duplicated. IMHO that shouldn't > happen. I > guess it's something Dell specific. > Is there anything I could do to help to get that fixed? Like offering > additional > information. > > -- > Regards, > Christian Ruppert > Role: Gentoo Linux developer, Bugzilla administrator and > Infrastructure member > Fingerprint: EEB1 C341 7C84 B274 6C59 F243 5EAB 0C62 B427 ABC8 -- Albert Chu ch...@llnl.gov Computer Scientist High Performance Systems Division Lawrence Livermore National Laboratory _______________________________________________ Freeipmi-users mailing list Freeipmi-users@gnu.org https://lists.gnu.org/mailman/listinfo/freeipmi-users