Thanks for the clarification. It made sense, but the results remain the same. The log still says 'Invalid Gateway' and 'sofia status' at the console does not show flowroute.
Dialplan: sofia/internal/1...@192.168.10.29:5090 Regex (PASS) [Long Distance - flowroute] destination_number(3235551212) =~ /^1?(\d{10})$/ break=on-false Dialplan: sofia/internal/1...@192.168.10.29:5090 Action set(effective_caller_id_number=13235555555) Dialplan: sofia/internal/1...@192.168.10.29:5090 Action set(effective_caller_id_name=${outbound_caller_id_name}) Dialplan: sofia/internal/1...@192.168.10.29:5090 Action bridge(sofia/gateway/flowroute/flowrouteAccount#13235551212) 2009-05-11 16:43:47 [DEBUG] switch_core_state_machine.c:114 switch_core_standard_on_routing() (sofia/internal/1...@192.168.10.29:5090) State Change CS_ROUTING -> CS_EXECUTE 2009-05-11 16:43:47 [DEBUG] switch_core_session.c:933 switch_core_session_signal_state_change() Send signal sofia/internal/1...@192.168.10.29:5090 [BREAK] 2009-05-11 16:43:47 [DEBUG] switch_core_state_machine.c:483 switch_core_session_run() (sofia/internal/1...@192.168.10.29:5090) State ROUTING going to sleep 2009-05-11 16:43:47 [DEBUG] switch_core_state_machine.c:397 switch_core_session_run() (sofia/internal/1...@192.168.10.29:5090) Running State Change CS_EXECUTE 2009-05-11 16:43:47 [DEBUG] switch_core_state_machine.c:490 switch_core_session_run() (sofia/internal/1...@192.168.10.29:5090) State EXECUTE 2009-05-11 16:43:47 [DEBUG] mod_sofia.c:173 sofia_on_execute() sofia/internal/1...@192.168.10.29:5090 SOFIA EXECUTE 2009-05-11 16:43:47 [DEBUG] switch_core_state_machine.c:151 switch_core_standard_on_execute() sofia/internal/1...@192.168.10.29:5090 Standard EXECUTE EXECUTE sofia/internal/1...@192.168.10.29:5090 set(open=true) 2009-05-11 16:43:47 [DEBUG] mod_dptools.c:748 set_function() sofia/internal/1...@192.168.10.29:5090 SET [open]=[true] EXECUTE sofia/internal/1...@192.168.10.29:5090 set(use_profile=nat) 2009-05-11 16:43:47 [DEBUG] mod_dptools.c:748 set_function() sofia/internal/1...@192.168.10.29:5090 SET [use_profile]=[nat] EXECUTE sofia/internal/1...@192.168.10.29:5090 set_user(defa...@192.168.10.29) EXECUTE sofia/internal/1...@192.168.10.29:5090 hash(insert/192.168.10.29-spymap/1000/924426fa-3e85-11de-9b6b-7ba002f89c82) EXECUTE sofia/internal/1...@192.168.10.29:5090 hash(insert/192.168.10.29-last_dial/1000/3235551212) EXECUTE sofia/internal/1...@192.168.10.29:5090 hash(insert/192.168.10.29-last_dial/global/924426fa-3e85-11de-9b6b-7ba002f89 c82) EXECUTE sofia/internal/1...@192.168.10.29:5090 set(effective_caller_id_number=13235555555) 2009-05-11 16:43:47 [DEBUG] mod_dptools.c:748 set_function() sofia/internal/1...@192.168.10.29:5090 SET [effective_caller_id_number]=[13235555555] EXECUTE sofia/internal/1...@192.168.10.29:5090 set(effective_caller_id_name=FreeSWITCH) 2009-05-11 16:43:47 [DEBUG] mod_dptools.c:748 set_function() sofia/internal/1...@192.168.10.29:5090 SET [effective_caller_id_name]=[FreeSWITCH] EXECUTE sofia/internal/1...@192.168.10.29:5090 bridge(sofia/gateway/flowroute/flowrouteAccount#13235551212) 2009-05-11 16:43:47 [ERR] mod_sofia.c:2531 sofia_outgoing_channel() Invalid Gateway 2009-05-11 16:43:47 [NOTICE] mod_sofia.c:2744 sofia_outgoing_channel() Close Channel N/A [CS_NEW] 2009-05-11 16:43:47 [DEBUG] switch_core_state_machine.c:559 switch_core_session_destroy_state() (N/A) State DESTROY 2009-05-11 16:43:47 [DEBUG] mod_sofia.c:240 sofia_on_destroy() N/A SOFIA DESTROY 2009-05-11 16:43:47 [DEBUG] switch_core_state_machine.c:559 switch_core_session_destroy_state() (N/A) State DESTROY going to sleep 2009-05-11 16:43:47 [ERR] switch_ivr_originate.c:1494 switch_ivr_originate() Cannot create outgoing channel of type [sofia] cause: [INVALID_NUMBER_FORMAT] From: freeswitch-users-boun...@lists.freeswitch.org [mailto:freeswitch-users-boun...@lists.freeswitch.org] On Behalf Of Brian West Sent: Monday, May 11, 2009 3:28 PM To: freeswitch-users@lists.freeswitch.org Subject: Re: [Freeswitch-users] Can't configure outbound call You want to collect 11 or 10 digits and send it out flowroute which requires 1+ number. The 1? makes the one optional. So now we only collect 10 digits and append the on in the bridge line. <extension name="Long Distance - flowroute"> <condition field="destination_number" expression="^1?(\d{10})$"> <action application="set" data="effective_caller_id_number=10000000000"/> <!-- If your provider does not provide ringback (180 or 183) you may simulate ringback by uncommenting the following line. --> <!-- action application="ringback" /--> <action application="bridge" data="sofia/gateway/flowroute/flowrouteAccount#1$1"/> </condition> </extension> /b On May 11, 2009, at 5:23 PM, Lars Zeb wrote: I'm sorry, but do not understand what it is that I should try. Are you saying to change the data attribute in the action command of the dialplan? Brian West br...@freeswitch.org -- Meet us at ClueCon! http://www.cluecon.com <http://www.cluecon.com/>
_______________________________________________ Freeswitch-users mailing list Freeswitch-users@lists.freeswitch.org http://lists.freeswitch.org/mailman/listinfo/freeswitch-users UNSUBSCRIBE:http://lists.freeswitch.org/mailman/options/freeswitch-users http://www.freeswitch.org