Chances are you need to get var us-ring then use that to set the transfer_ringback

/b

On Jun 24, 2009, at 9:20 AM, Diego Toro wrote:

Hi Brian, with Session.SetVariable("transfer_ringback", ${us-ring}); I have message: "[CRIT] switch_channel.c:633 Invalid data ($ {transfer_ringback} contains a variable)".

Using from managed code:

string stUsRing = _Session.GetVariable("us-ring");
Session.SetVariable("ringback", stUsRing);
Session.SetVariable("transfer_ringback", stUsRing);

The bridge works fine.

The question is, using Session is not possible acces directly global vars way ${var_name} ?

Thanks