Did this work? Would love an update on this error/issue.

  _____  

From: Michael Jerris [mailto:[email protected]] 
Sent: Wednesday, June 24, 2009 8:15 AM
To: [email protected]
Subject: Re: [Freeswitch-users] Nibblebill and multiple gateway


try adding  
<action application="set" data="import=nibble_rate"/>
before the bridge and report back results.


Mike


On Jun 24, 2009, at 1:36 AM, Dome Charoenyost wrote:


Dear All,

Look like nibblebill does't work with multiple gatreway.
I try 
        <action application="set" data="nibble_account=0838833133"/>

        <action application="bridge"
data="{absolute_codec_string='GSM,G729'}[nibble_rate=0.3]sofia/external/6626
[email protected]|[nibble_rate=0.5]sofia/external/[email protected]
x.xxx>

nibblebill not found nibble_rate

But 
        <action application="set" data="nibble_rate=0.05"/>  
        <action application="set" data="nibble_account=0838833133"/>

        <action application="bridge"
data="{absolute_codec_string='GSM,G729'}sofia/external/[email protected]
x.xxx|sofia/external/[email protected]>
  
Work fine

What's difference from set application and []  ?

Best Regards.
Dome C.
_______________________________________________
Freeswitch-users mailing list
[email protected]
http://lists.freeswitch.org/mailman/listinfo/freeswitch-users
UNSUBSCRIBE:http://lists.freeswitch.org/mailman/options/freeswitch-users
http://www.freeswitch.org



_______________________________________________
Freeswitch-users mailing list
[email protected]
http://lists.freeswitch.org/mailman/listinfo/freeswitch-users
UNSUBSCRIBE:http://lists.freeswitch.org/mailman/options/freeswitch-users
http://www.freeswitch.org

Reply via email to