hi our freeswitch server has to talk to a sonus ip-switch when we want to setup a call we do get a "100 Trying" and then a "180 Ringing" within the "180 Ringing" we get a sdp with "a=sendonly" then our freeswitch quits with a CANCEL message. i simply don't get why our freeswitch aborts the session - i think it would work if no "a=sendonly" would be present in the sdp.
my technical contact doesn't want to switch 180 to 183 on the sonus side - this would also work (i think). in fact he says that 180 ringing is vaild, he isn't that wrong in this case. our freeswitch works in proxy mode, we do use trunk 15396 see a ngrep trace under http://pastebin.freeswitch.org/11235 92.63.208.36 - freeswitch 38.105.229.100 - sonus br -- Ing. Christian Löschenkohl Technische Leitung, Forschung & Entwicklung VoIP xpirio Telekommunikation & Service GmbH Lakeside B04 9020 Klagenfurt Austria T +43 (0) 5 77 11 - 1000 F +43 (0) 5 77 11 - 1002 E christian.loeschenk...@xpirio.com _______________________________________________ FreeSWITCH-users mailing list FreeSWITCH-users@lists.freeswitch.org http://lists.freeswitch.org/mailman/listinfo/freeswitch-users UNSUBSCRIBE:http://lists.freeswitch.org/mailman/options/freeswitch-users http://www.freeswitch.org