Bonjour,
je ne m'explique pas cette situation :
sh int e 35 transceiver
If device is externally calibrated, only calibrated values are printed.
N/A: not applicable, Tx: transmit, Rx: receive.
mA: milliamperes, dBm: decibels (milliwatts).
Bias Optical Optical
Temp Voltage Current Tx Power Rx Power
Port (Celsius) (Volts) (mA) (dBm) (dBm) Last Update
----- --------- -------- -------- -------- --------
-------------------
Et35 20.10 3.36 14.55 -6.03 -6.77 0:00:00 ago
sh int e 35
Ethernet35 is down, line protocol is down (notconnect)
Hardware is Ethernet, address is 444c.a830.be8c (bia 444c.a830.be8c)
Ethernet MTU 9214 bytes , BW 1000000 kbit
Full-duplex, 1Gb/s, auto negotiation: off, uni-link: disabled
Down 9 hours, 6 minutes, 44 seconds
Loopback Mode : None
11 link status changes since last clear
Last clearing of "show interface" counters never
5 minutes input rate 0 bps (0.0% with framing overhead), 0 packets/sec
5 minutes output rate 0 bps (0.0% with framing overhead), 0 packets/sec
37272716 packets input, 10241947883 bytes
Received 42494 broadcasts, 27 multicast
0 runts, 0 giants
0 input errors, 0 CRC, 0 alignment, 0 symbol, 0 input discards
0 PAUSE input
61085627 packets output, 56045279287 bytes
Sent 0 broadcasts, 4264681 multicast
0 output errors, 0 collisions
0 late collision, 0 deferred, 0 output discards
0 PAUSE output
Le port en face est up.
Quelque'un peut il m'expliqué ?
Merci
---------------------------
Liste de diffusion du FRnOG
http://www.frnog.org/