Le 02/05/2014 17:36, Vincent LOUPIEN a écrit :
Hello,

We use GLPI v0.84.5 with the plugin FusionInventory v0.84+2.1 .

When information feedback through an SNMP inventory (via agent v2.3.6 or now 
v2.3.7) on HP Networking 2910 switchs, we don't get the same result for 
equipment with the same version of firmware (W.14.70) and similar overall 
configuration. The information reported in the FusionInventory SNMP party seem 
correct on one equipment and incoherent on several others. Someone there a 
similar experience or idea or it could come from?

I am ready to send the snmpwalk and configurations of such equipment to people 
who wish to make their help.

Thank you in advance for your answers :-)
You can send snmpwalk output for both kind of equipment (the one with correct result, and one for any of the incorrect ones) to [email protected], I'll have a look at what is wrong, and I'll add them to our hardware samples database.

--
Guillaume

_______________________________________________
Fusioninventory-user mailing list
[email protected]
http://lists.alioth.debian.org/cgi-bin/mailman/listinfo/fusioninventory-user

Reply via email to