Paul,
Is fwm running? I don't use a Nokia, but in the non-Nokia world, the fw manager is the
one listening on that port, not the fw module.
As for the user, don't you need to configure users on the fw manager for the GUI to
login?
Robert
- -
Robert P. MacDonald, Network Engineer
G o r d o n F o o d S e r v i c e
Voice: +1.616.261.7987 email: [EMAIL PROTECTED]
>>> "Paul Ellis" <[EMAIL PROTECTED]> 6/1/00 3:02:32 PM >>>
>
>Seeking assistance please:
>
>Setup
>-----
>Client workstation is running ver. 4.1 of mgmt GUI.
>FW-1 box (nokia ip440) is running ver. 4.1 of FW-1.
>License is installed (worked okay)
>ethernet interfaces configured properly on FW-1 box.
>Can browse to http server on FW-1 box from client workstation.
>fwd Is running on FW-1 box.
>have set up user/passwd for the login (user can telnet to FW-1 box)
>
>Symptoms
>--------
>netstat show GUI tries to connect to nokia FW-1 box on TCP 258,
>but No Daemon is listening on that port on the FW-1 box!
>
>error msg is just "can't connect to server"
>
>***--Can anyone tell me, pls, how to get the gui to connect?
>
>Thanks for any assistance.
>
>Paul Ellis
>[EMAIL PROTECTED]
>unix ops engineer
================================================================================
To unsubscribe from this mailing list, please see the instructions at
http://www.checkpoint.com/services/mailing.html
================================================================================