Ben Rockwood wrote:
> The strange thing is that if you just refresh the gmeta cluster page 
> you'll see nodes going up and down in a sine fashion... 15 down 10 up, 
> refresh, 14 down 11 up, refresh, 13 down 12 up, [...].

I have only seen behavior like this when there are two data_source lines 
in gmetad.conf listening to the same port.

It's not a scalability problem with the software itself, I've seen 
unicast clusters of hundreds of machines that had no problems.


-------------------------------------------------------------------------