Thanks, Thomas We see that in practice but I have never seen it documented. Do you know of any published data on load response?
Tom From: Gasification [mailto:[email protected]] On Behalf Of Thomas Koch Sent: Tuesday, July 09, 2013 7:43 AM To: Discussion of biomass pyrolysis and gasification Subject: Re: [Gasification] Mini Grid Load Following With a Biomass Gasifier Tom Load response on small gasifiers fixed bed downdraft or fixed bed staged gasifiers I assume - is extremely good as there is a large inventory of char. The principle is used for automobiles. Most of these gasifiers can go from 10 % lo0ad to 80 % load with in a few seconds. Best regards Tom Fra: Gasification [mailto:[email protected]] På vegne af Tom Miles Sendt: 9. juli 2013 16:38 Til: Discussion of biomass pyrolysis and gasification Emne: [Gasification] Mini Grid Load Following With a Biomass Gasifier Does anyone have any experience or data to comment on the load response of biomass gasifiers? Were looking at using a gasifier on a mini-grid in a remote community. The utility is looking for data to confirm that a biomass fired generator can follow load changes on a minute to minute basis. The gasifiers will be in the size range of 50-500 kWe. Thanks Tom Miles
_______________________________________________ Gasification mailing list to Send a Message to the list, use the email address [email protected] to UNSUBSCRIBE or Change your List Settings use the web page http://lists.bioenergylists.org/mailman/listinfo/gasification_lists.bioenergylists.org for more Gasifiers, News and Information see our web site: http://gasifiers.bioenergylists.org/