Dear Tom

Indeed, the direct combustion boiler system is appropriate for steam 
generation. This is a case in China. I was told that the local government is 
promoting the clean energy, and biomass gasifiction is acceptable, but direct 
combustion system is unfavorable. In addition, the feedstock, paper reject 
(without pelletization) contains a large amount of light fragments, and is 
difficult to apply the fluidized bed. The light fragments will "fly" into the 
freeboard of the fluidized bed, not within the bed.


Thanks.


Keng-Tung

?



________________________________
從: Gasification <[email protected]> 代表 Tom Miles 
<[email protected]>
寄件日期: 2014年09月29日 23:22
至: 'Discussion of biomass pyrolysis and gasification'
主旨: Re: [Gasification] Biomass gasification system for heat applications

Keng-Tung,

IS there a particular reason why you are looking for a gasifier? A fluidized 
bed combustor-boiler may be more appropriate for steam generation at this scale.

Tm

From: Gasification [mailto:[email protected]] On 
Behalf Of [email protected]
Sent: Monday, September 29, 2014 12:08 AM
To: [email protected]
Subject: [Gasification] Biomass gasification system for heat applications

Dear all,

We are looking for a biomass gasification system for heat applications based on 
the following specification:

Feedstock: 120 t/d paper reject (LHV=6,500 kcal/kg) (non-pellet)
Function: providing low pressure steam for the process
Steam capacity: 20 t/h Steam
Steam pressure: 8 bar

Do anyone know which company can provide the above system? Thank you very much 
for your kind assistance indeed.

I also heard that Foster Wheeler and Lurgi will no longer provide biomass 
gasification systems. Is it true?

Best wishes

Keng-Tung
Taiwan
[email protected]<mailto:[email protected]>?


本信件可能包含工研院機密資訊,非指定之收件者,請勿使用或揭露本信件內容,並請銷毀此信件。
This email may contain confidential information. Please do not use or disclose 
it in any way and delete it if you are not the intended recipient.


====================================================================
本信件可能包含工研院機密資訊,非指定之收件者,請勿使用或揭露本信件內容,並請銷毀此信件。 
This email may contain confidential information. Please do not use or disclose 
it in any way and delete it if you are not the intended recipient.
_______________________________________________
Gasification mailing list

to Send a Message to the list, use the email address
[email protected]

to UNSUBSCRIBE or Change your List Settings use the web page
http://lists.bioenergylists.org/mailman/listinfo/gasification_lists.bioenergylists.org

for more Gasifiers,  News and Information see our web site:
http://gasifiers.bioenergylists.org/

Reply via email to