Christian Riggenbach wrote:
> hi list
>
> i use some parts in my layout which have brackets in their labels of the pins
> (like AtMega128, for example "PE0 (RXD0/PDI)"). when i transport the schema
> to pcb (with xgsch2pcb / gsch2pcb), the m4-processor in pcb gets confused
> about the brackets the command "ChangePinName(A10/K1, 2, PE0 (RXD0/PDI))" in
> **Schema**.cmd (coppied out of the file). the result is, that the closing
> bracket of the label isn't displayed, like "PE0 (RXD0/PDI".
>
> the question is: Can someone fix this? it should't be that heck of a fix, but
> i simply don't have any knowledge in guile.
>
> when requested, i would send my schemas and pcb to anyone interested in this.
Will
ChangePinName(A10/K1, 2, "PEO (RXD0/PDI)")
in the .cmd file work? Acutally I wonder if the refdes should be quoted
too like:
ChangePinName("A10/K1", 2, "PEO (RXD0/PDI)")
If that works for you then I can fix the guile bit.
-Dan
_______________________________________________