Christian Riggenbach wrote:
> hi list
> 
> i use some parts in my layout which have brackets in their labels of the pins 
> (like AtMega128, for example "PE0 (RXD0/PDI)"). when i transport the schema 
> to pcb (with xgsch2pcb / gsch2pcb), the m4-processor in pcb gets confused 
> about the brackets the command "ChangePinName(A10/K1, 2, PE0 (RXD0/PDI))" in 
> **Schema**.cmd (coppied out of the file). the result is, that the closing 
> bracket of the label isn't displayed, like "PE0 (RXD0/PDI".
> 
> the question is: Can someone fix this? it should't be that heck of a fix, but 
> i simply don't have any knowledge in guile.
> 
> when requested, i would send my schemas and pcb to anyone interested in this.

Will

ChangePinName(A10/K1, 2, "PEO (RXD0/PDI)")

in the .cmd file work?  Acutally I wonder if the refdes should be quoted 
too like:

ChangePinName("A10/K1", 2, "PEO (RXD0/PDI)")


If that works for you then I can fix the guile bit.

-Dan


_______________________________________________
geda-dev mailing list
[email protected]
http://www.seul.org/cgi-bin/mailman/listinfo/geda-dev

Reply via email to