this is a feature should be built into the core of the footprints, as not all pins need to be connected, it would be nice to have the ability to specify that a net list has options
connect to either pin 1 or pin 2 and either exclusively or inclusively. just a thought on this topic. Steve On 4/22/07, John Luciani <[EMAIL PROTECTED]> wrote:
On 4/22/07, Peter Clifton <[EMAIL PROTECTED]> wrote: > On Sun, 2007-04-22 at 12:11 +0200, Stefan Salewski wrote: > > > > How can I handle this? Is there a way to generate a footprint with > > internally connected pins? > > I believe you can just make the footprint as usual, but instead of > numbering the pins uniquely, you assign the connected ones the same > number. Peter is correct. I do this all the time. It is especially useful when you need to overlay a pin and a pad. (* jcl *) -- http://www.luciani.org _______________________________________________ geda-user mailing list [email protected] http://www.seul.org/cgi-bin/mailman/listinfo/geda-user
_______________________________________________ geda-user mailing list [email protected] http://www.seul.org/cgi-bin/mailman/listinfo/geda-user